AUX Air Conditioner Service manual
3
ASW-H09A+12A4/HS2R-V
Model No
Items
Indoor Unit A
(System A)
Indoor Unit B
(System B)
Outdoor Unit
Type
Wall mounted model Heating pump
Cooling kw
3.2
2.5
/
Dehumidify kg/h 1.2 1.0 /
Heating kw
3.6
2.75
/
Noise level
dB(A)
43
40
62
Cooling 2.3
2.3
/
Performance
EER
Heating
W/W
2.4 2.4 /
Power supply
φ
-V-Hz
1 / 220-240V~/ 50Hz
Cooling 1320
970
2150
Rated input
Heating
W
1360 1070 2300
Cooling 5.74
4.22
9.35
Rated current
Heating
A
5.91 4.65 10
Length m
2
2
4.8
Supply cord
Class
/
250V 10A
250V 10A
400V 25A
Starting Current
A
30.5
21.7
/
Electrical Data
Fuse capacity
A 3.15
3.15
3
.15
Refrigerant/Charge g
R407c/1100 R407c/980 /
Type /
Rotary
Rotary
/
Model /
4KS225EBB 4PS164EAC
/
Rated input W
1300/1325
920/945
/
Compressor
Overload
Protector
/ Inner
B165-150-241H
/
Heat exchanger
Row*Hole
2*12
2*10
2*31
Type Capillary
tube
Refrigerating System
Expansion device
Specification(mm)
φ
3.0*500+
φ
3.0*500
φ
2.6*350+
φ
2.6*300
/
Air Volume
m3/h
620
420
/
Cooling r/min
1180/1050/950/800
1080/950/900/800
860
Fan Speed
H/M/L/Q
Heating r/min
1180/1050/950/850
1080/950/900/850
860
Fan type
/
Cross flow
Cross flow
Propeller fan
Fan System
Fan motor output
W
19
19
6
8
Connecting
Pipe
Gas /Liquid OD(mm)*L(mm)
Φ
9.52×5000/
Φ
6.35×5000
Connection
Drainage Pipe
OD(mm)*L(mm)
Φ
14×780
Suitable area
m2
12-21
12-17
/
Net dimensions
(W x H x D)
mm 89.2*29.6*17.6
80.2*26.2*16.5
331*846*901
Others
Net weight
kg
10.5
9.5
70
Summary of Contents for EA Series
Page 1: ...AUX One to Two Split Air Conditioner Service Manual EA EL HS Series ...
Page 48: ...AUX Air Conditioner Service manual 46 9 Fault analysis of major parts ...
Page 58: ...AUX Air Conditioner Service manual 56 b Single Cooling Model ...
Page 60: ...AUX Air Conditioner Service manual 57 Section 10 Service Record Date Page Part Cause Report ...