AUX Air Conditioner Service manual
36
component.
14. As in figure 10.dismantle the four bolts on the fixed partition plate. and take down partition plate
15. Unsolder the 4 welding points shown in chart 11.
16. As shown in chart 12. dismantle condenser assembly. A. B system compressor and valve plate
component.
figure10 figure11
figure12 figure13
figure14
17. When reconnecting the connecting pipes of inside and outside unit. please strictly follow chart 14.
A system match with A indoor unit.B system match with B indoor unit. Change them is prohibited.
Summary of Contents for EA Series
Page 1: ...AUX One to Two Split Air Conditioner Service Manual EA EL HS Series ...
Page 48: ...AUX Air Conditioner Service manual 46 9 Fault analysis of major parts ...
Page 58: ...AUX Air Conditioner Service manual 56 b Single Cooling Model ...
Page 60: ...AUX Air Conditioner Service manual 57 Section 10 Service Record Date Page Part Cause Report ...