32
LED
ons for faults
l
igh
ing abnormal
ircuit
ing abnormal
abnormal
ion
waving angle for electrical machine of E series
door will full open first, then wave to the original position
aving scope for heating is 50°, such as (diagram 1) between 3 and
5.5°/s
the model and start to work, wind door will open, and before this, wind door stops at
, when resetting indoor motor stops.
2 shinning times possible reas
⑴
.outdoor temperature sensor abnormal
⑵
.outdoor defrosting sensor abnormal
⑶
.compressor venting temperature abnorma
⑷
.compressor venting temperature too h
⑸
.outdoor communication abnormal’
⑹
.communicating with IPDU module abnormally
⑺
.E
2
PROM data abnormal
⑻
.IPDU abnormal; exceeding max turning value
⑼
.IPDU abnormal; shaking
⑽
.IPDU abnormal; off position
⑾
.IPDU abnormal; accelerat
⑿
.IPDU abnormal; G-TR short c
⒀
.IPDU abnormal; position checking return
⒁
.IPDU abnormal; electricity sensing
⒂
.IPDU abnormal; compressor locked
⒃
.IPDU abnormal; compressor damaged
10. Wind Door Waving Angle Definit
(diagram 1) 48G(excluding 48G) below is
hanging air conditioner
1
、
when connected to electricity wind door will appear to full closing, waving speed is 22°/s
2
、
After turned on, wind
accordingly, when heating , it stops at (diagram 1) position 5, while refrigerating, it will return to
(diagram 1) position 2.
3
、
wind door button on the remote control can be set to be free waving hand waving.
4
、
when free waving, w
5, waving scope for refrigerating is 50°, (diagram 1) between 2 and 4, waving speed is
5
、
when connected to electricity, and remote control does not set wind door to wave, the
waving angle will move to the position according to different models and fix position, for
example,,(diagram 1) position 2 is refrigerating model, (diagram 1) position 5 is heating
model, after
风机
starting up, wind door will recover to free waving; while remote control
set wind door as hand waving, the waving angle will not change all the time.
6
、
wind door will close automatically, after being turned off and indoor motor stops
working
7
、
pressing enforcing starting button to go into the automatical model, after system choose
refrigerating base position.
8
、
when being connected to electricity and model exchanging, wind swing will reset to the
direction of closing one time
9
、
when heating is breeze, wind door is forced to horizontal position wind door
waving angle for new production style E
Summary of Contents for ASW-H09A4/SAR1DI
Page 1: ...FOR Split Wall Mounted Series R410a DC Inverter ASW H09A4 SAR1DI ASW H12A4 SAR1DI 2008 ...
Page 6: ...Remote Controller Instructions 4 ...
Page 7: ...5 ...
Page 8: ...6 ...
Page 9: ...7 ...
Page 10: ...8 ...
Page 11: ...9 ...
Page 12: ...10 ...
Page 13: ...11 ...
Page 14: ...12 ...
Page 15: ...13 ...
Page 16: ...14 ...
Page 17: ...15 ...
Page 42: ...Exploded Pictures 1 Indoor unit exploded picture ASW H09A4 SAR1DI 40 ...
Page 44: ... 2 Outdoor unit exploded picture ASW H09A4 SAR1DI 42 ...
Page 46: ... 3 Indoor unit exploded picture ASW H12A4 SAR1DI 44 ...
Page 48: ... 2 Outdoor unit exploded picture ASW H12A4 SAR1DI 46 ...