Brief Introduction Of Installation
The installation of air-conditioner should meet with the “Installation Instruction”. The machine
must be installed correctly by professional technicians according to the “Installation
Instruction”.
(1) Guide to customer
①
The customer should provide a suitable power supply source, its voltage should be in the
range of 90-110% of its rated voltage.
②
The power supply circuit should have MCB leakage protection. The capacity should be
more than 1.5 times of the maximum current.
③
Must use independent circuit and suitable grounding socket matching with the plug of
air-conditioner.
④
The wiring must be installed by qualified electrician according to the electrical safety
requirements.
⑤
The air-conditioner must be well grounded, the switch of the main power of air-conditioner
must be reliably grounded.
⑥
The power supply wire, must be changed by qualified electrician.
(2) Installation Instruction
1. Installation order
Selection of the installation position Installing the air-conditioner
16
Expelling the air in the pipes and the indoor unit Connecting the pipes and wires
Testing
2. Selection of the installation position
Indoor Unit:
①
There is no heating and steaming source nearby.
②
No obstacles for installation position from nearby.
③
Keep good air circulation.
④
Convenient to adopt measures to reduce noises.
⑤
Don’t install them near the doorway.
⑥
Make sure to have the distance specified in the picture between the ceiling, wall, furniture
and other obstacles.
⑦
2 meters high above the floor.
Outdoor Unit:
①
In case that you put up a canopy to protect it from rains and sunrays, pay attention not to
cause any obstacles for the heating dispersion for the condenser.
②
Don’t keep animals or plants near the installation location for the hot air from the outdoor
unit will affect them.
③
Make sure to have the distance specified in the picture between ceiling, wall, furniture and
other obstacles.
④
Stay away from heating source and inflammable air.
⑤
The installation base and supporting frame should be strong and secure. The machine
should be at a level surface.
Summary of Contents for ASW-H09A4/SAR1DI
Page 1: ...FOR Split Wall Mounted Series R410a DC Inverter ASW H09A4 SAR1DI ASW H12A4 SAR1DI 2008 ...
Page 6: ...Remote Controller Instructions 4 ...
Page 7: ...5 ...
Page 8: ...6 ...
Page 9: ...7 ...
Page 10: ...8 ...
Page 11: ...9 ...
Page 12: ...10 ...
Page 13: ...11 ...
Page 14: ...12 ...
Page 15: ...13 ...
Page 16: ...14 ...
Page 17: ...15 ...
Page 42: ...Exploded Pictures 1 Indoor unit exploded picture ASW H09A4 SAR1DI 40 ...
Page 44: ... 2 Outdoor unit exploded picture ASW H09A4 SAR1DI 42 ...
Page 46: ... 3 Indoor unit exploded picture ASW H12A4 SAR1DI 44 ...
Page 48: ... 2 Outdoor unit exploded picture ASW H12A4 SAR1DI 46 ...