if 7
≤
Te <11 ,
℃
℃
the frequency of the compressor will increase in the rate of 1Hz/10s
frequency
if 6
≤
Te <7 ,
℃
℃
the compressor frequency remains unchanged;
if 0 <Te <6 ,
℃
℃
the frequency of the compressor will decline in
the rate of 1Hz/10s
if Te
≤
0 , and it goes o
℃
n for more than 2 min, then the compressors and outdoor fans will
stop working, but the indoor fan and the wind door will still operate normally in a weak speed .
When the compressor stop running over 3 min, and Te
≥
11 , the compressor resume
℃
normal operation;
0℃
5℃
9℃
11
℃
7
℃
Normal operation
unchanged
Speed of frequency reduce and increase
:
1Hz/10s
Turn off after maintaining for 2 min
unchanged
The frequency reduce
The frequency decrease
Te
Te
6
℃
The frequency increase
3
、
The overheating protection of indoor coil while heating
Te rise:
if Te
≥
65 , and it goes on for more than 5 s, then it will stop working
℃
if 56
≤
Te <65 , the frequency of the compressor will decline in the rat
℃
℃
e of 1Hz/3s.
Te decline:
if 52 <Te
≤
55 , the compressor frequency remains unchanged
℃
℃
if 48 <Te
≤
52 , the frequency of the compressor will increase in the rate of 1Hz/30s.
℃
℃
When the compressor stop running over 3 min, and Te
≤
48 , the compressor
℃
will resume
normal operation;
48℃
52℃
55℃
56℃
53℃
49℃
65℃
Increase by 1Hz/30s
unchanged
Decrease by 1Hz/3s
Normal operaion
Turn off after maintaining for 5 sec
4
、
The overheating protection of compressor 5 min after the compressor starts to work,
If 85
≤
Td <90 , the frequency of the compressor will increase in the rate of 1Hz/30s.
℃
℃
29
≥
95
of 1Hz/3s.
If Td
≥
110 , the compressor will stops immediately .
℃
If 90
≤
Td <95
℃
℃
, the compressor frequency remains unchanged;
If Td
, the frequency of the compressor will decline in the rate
℃
Summary of Contents for ASW-H09A4/SAR1DI
Page 1: ...FOR Split Wall Mounted Series R410a DC Inverter ASW H09A4 SAR1DI ASW H12A4 SAR1DI 2008 ...
Page 6: ...Remote Controller Instructions 4 ...
Page 7: ...5 ...
Page 8: ...6 ...
Page 9: ...7 ...
Page 10: ...8 ...
Page 11: ...9 ...
Page 12: ...10 ...
Page 13: ...11 ...
Page 14: ...12 ...
Page 15: ...13 ...
Page 16: ...14 ...
Page 17: ...15 ...
Page 42: ...Exploded Pictures 1 Indoor unit exploded picture ASW H09A4 SAR1DI 40 ...
Page 44: ... 2 Outdoor unit exploded picture ASW H09A4 SAR1DI 42 ...
Page 46: ... 3 Indoor unit exploded picture ASW H12A4 SAR1DI 44 ...
Page 48: ... 2 Outdoor unit exploded picture ASW H12A4 SAR1DI 46 ...