PC data stream 1
Enables the data stream to a serial port.
When disabled, the port is not opened.
This is bi-directional so can be data stream output or input from another acquisition
system using ECU data stream format.
•
If want to force data stream comm port number then see Help menu, "Trouble
shooting" for command line parameter.
•
If cannot read/send data with some USB serial ports, press "OK" again to re-
initialise the data stream.
Open logged file
Opens data log files that have be saved to disk.
•
Data log files may be ECU data log file or PC data log files as this program treats
them the same.
You can overlay other logged files on top of the current data & offset them with time so
can compare. Parts of the data can be marked & minimum, maximums, mean, Rate &
standard deviation are calculated. Can export as comma separated value
From data log files, can create XY plots with filters, Histograms & if logged LOAD,
Throttle & A/F ratio can create mixture plots. Mixture plots are shown as text & graphical
form. From mixture plots can correct "Base fuel delivery" table via the "F5" key. See
Edit-window for more details.
If table opened with same axis variables as logged data then an orange cursor shows the
table position.
To jump to graph TABS press "L" go forward & K go backwards.
Virtual drive
Opens a data log file & then you can create dials, bar graphs or plain displays plus time
or XY strip charts.
Sizing of instruments are on the bottom right of focused instrument. See Edit-Window for
options once file opened. Virtual drive instrument setup screen is automatically saved to
disk when exiting. If logged variables correspond to table axis variables, the logger
cursor will be shown in the table.
ECU Logger setup
ECU data logger setup:-
Channels:
Select items to data log. The more items logged the more memory is used
and the total log time is reduced.
Sample/Sec
:
Samples per second each item is recorded.
Memory mode
Protected.-When memory is full logging will stop.