5-44

Removing Zones, Conditions, Actions and Overlays

Zones

Removing a zone removes any conditions and actions assigned to the zone.
1. On the Zone Setup screen, select the zone.
2. Click 

R

EMOVE

 Z

ONE

 in the Commands section or the X to the right of the 

zone description in the Easy Setup, Zones Explorer or Actions Explorer 

sections.

3. Click 

A

PPLY

 C

HANGES

.

Conditions

Removing a condition removes any actions/outputs associated with the 

condition.
1. Select the condition.
2. In the 

E

ASY

 S

ETUP

 section, deselect the check box, or in the Zones Explorer 

or Actions Explorer sections, click the X to the right of the condition 

description.

3. Click 

A

PPLY

 C

HANGES

.

Display Actions

Display actions are automatically removed if the zone or condition associated 

with it is removed.
1. In the Zones Explorer or Actions Explorer sections, click the X to the right of 

the color blocks.

2. Click 

A

PPLY

 C

HANGES

.

Output Assignments

Output assignments are automatically removed if the zone or condition 

associated with it is removed. 
1. In the Zones Explorer or Actions Explorer sections, click the X to the right of 

the assignment block.

2. Click 

A

PPLY

 C

HANGES

.

Video Overlays

1. For standard overlays, in the Video Overlays section, deselect the check box 

for the overlay or click the text on the video image, then click the X on the 

right side.

2. For LED overlays, click the LED symbol in the Actions Explorer or click the 

text on the video image, then click the X on the right side.

3. For static text overlays, click the text on the video image, then click the X on 

the right side.

4. Click 

A

PPLY

 C

HANGES

.

Summary of Contents for Image Sensing IntelliSight

Page 1: ...Autoscope IntelliSight User Guide 2022 Image Sensing Systems Inc A700 7131 Rev B...

Page 2: ...trademark of Image Sensing Systems Inc registered in the United States and other countries Autoscope IntelliSight is a trademark of Image Sensing Systems Inc All other product names referenced in this...

Page 3: ...1 6 Ethernet Port LEDs 1 6 IntelliSight Processor Status LED 1 6 Autoscope I O Module 1 7 LEDs 1 8 Connectors 1 9 Jumper Pins 1 10 Rear Connector 1 11 Supervisor Software 1 13 Accessing Online Help 1...

Page 4: ...resence Zone 5 12 Add Zones From Calibration 5 13 Add Zones Manually 5 15 Adding an Advance Presence Zone 5 20 Adding Receding Traffic Zones 5 22 Adding a Pedestrian Crosswalk Zone 5 24 Adding a Pedes...

Page 5: ...Network 6 12 Outputs Phases Failsafe and All Call For IntelliSight Devices 6 12 Assigning Outputs 6 12 Failsafe Operations 6 13 Port Forwarding 6 15 Restart Device 6 15 Set Time 6 16 Streaming Video F...

Page 6: ...n three decades of proven above ground video detection experience Autoscope IntelliSight delivers the highest levels of innovation and performance in an easy to use detection solution that supports a...

Page 7: ...om the power supply is connected This provides the power required for the IntelliSight Processor and connected IntelliSight Cameras to operate This can be screwed in to prevent from disconnection or r...

Page 8: ...applied to the IntelliSight Processor 3 System Status LED Used for diagnostic and status purposes see Status LED on page 1 6 4 HDMI Port reserved for future use 5 Two standard USB ports Currently use...

Page 9: ...IntelliSight Camera Table 1 3 IntelliSight Camera Specifications Item Description Electrical Power PoE to cameras via provided switch Environmental Temperature range 40 C to 60 C 40 F to 140 F Humidi...

Page 10: ...type of address is defined through the Supervisor For information on defining the IP address see Add Device by IP on page 6 5 I O Port The I O port is used to communicate to the Autoscope I O card wh...

Page 11: ...ernet Port LEDs There are two LEDs associated with each RJ 45 port items 6 7 8 9 and 10 in Table 1 2 on page 1 3 which indicate the speed of the network connection and activity as follows Left LED 100...

Page 12: ...O Module The Autoscope I O Module is an optional card that converts detection data from the IntelliSight Processor to standard wired inputs and outputs in the traffic cabinet The Module is shown in F...

Page 13: ...ntelliSight Processor are OK Not lit The I O Module is powered off Table 1 4 Autoscope I O Module Specifications Item Description Electrical Power input 12 VDC min 50 VDC max Current draw 500ma maximu...

Page 14: ...Output 22 Output 35 5 Output 4 Output 55 27 Output 23 Output 36 6 Output 5 Output 56 28 Output 24 Output 37 7 Output 6 Output 57 29 Input 1 Output 38 8 Output 7 Output 58 30 Input 2 Output 50 9 Output...

Page 15: ...r Pin Locations Table 1 6 Jumper Chart Default Settings Jumper Jumper Across Pins 1 2 Jumper Across Pins 2 3 Factory Default JP1 Output Failsafe Enable Output Failsafe Disable 1 2 JP2 Power Loss Fails...

Page 16: ...utput 38 NC 3 Input 2 Output 37 NC 4 Input 3 Output 36 NC 5 Input 4 Output 35 NC 6 Input 5 Output 34 Output 64 7 Input 6 Output 33 Output 63 8 Input 7 Output 32 Output 62 9 Input 8 Output 31 Output 61...

Page 17: ...put 18 Output 48 23 NC Output 17 Output 47 24 Output 8 Output 16 Output 46 25 Output 7 Output 15 Output 45 26 Output 6 Output 14 Output 44 27 Output 5 Output 13 Output 43 28 Output 4 Output 12 Output...

Page 18: ...o access the help system press F1 on the keyboard A separate window appears with the help page for the screen currently being displayed in the Supervisor Various tabs provide for locating and displayi...

Page 19: ...rs when it determines it is not able to perform detection or when the zoom setting for the camera is changed Output the signal sent to the Controller when the condition is met Recall what occurs when...

Page 20: ...per Tie wraps for cable strain relief Radios or cell phones to communicate between the cabinet and the bucket truck Computer and Ethernet network cable Faceplate cleaning supplies lint free lens tissu...

Page 21: ...ends with Rj 45 connectors NOTE A maximum of four IntelliSight Cameras can be connected to the IntelliSight Processor Use the following guidelines to install the Ethernet cable between the IntelliSig...

Page 22: ...Placement The camera should be located horizontally on the mast arm or luminaire arm in a level position and aimed towards approaching traffic The actual alignment will depend on the number of lanes a...

Page 23: ...nt along the desired lane line is not possible shift to the nearest lane line towards the center of the field of view Two or Three Lanes Four Lanes with Left Turn Aim here Thru lane 2 or 3 Thru lane 1...

Page 24: ...ttings during the aiming procedure For example in Figure 2 5 and Figure 2 6 the camera Cam is set to detect southbound traffic The solid green line represents where the camera should be aligned when i...

Page 25: ...Chapter 2 Pre Installation Considerations Autoscope IntelliSight User Guide 2022 Image Sensing Systems Inc 2 6 Figure 2 6 Alternative field of view N S W E Cam...

Page 26: ...n this sequence the IntelliSight Cameras are installed followed by the IntelliSight Processor and then if required the IntelliSight I O Module Warning Hazard of damage to personnel and system componen...

Page 27: ...power supply to the IntelliSight Processor and the PoE switch The power supply will have V1 and V2 connections Connect the red wire to V and the black wire to V1 on the power supply Then connect the r...

Page 28: ...ocessor and the PoE switch If desired a circuit breaker can be installed before the connection to the power supply 6 Connect a laptop to the maintenance port of the Processor before moving on to Camer...

Page 29: ...How to remove external sunshade 2 If using an external mount or conduit fixing hole and banding directly to pole or mast arm feed the network cable through the access hole If banding to the pole feed...

Page 30: ...5 connector on the end of the Cat5e or Cat6 cable Use the RJ45 cap to feed the cable through the included grommet Then slightly pull it back to seal it properly 4 Install the adapter box mounting pin...

Page 31: ...the camera and level it Then tighten the screws until they are snug enough that the camera does not move See Field of View FOV on page 2 5 for guidance 8 Connect the camera to the POE switch in the ca...

Page 32: ...rs include Microsoft Edge IE mode Microsoft Edge Chrome Firefox and Internet Explorer 12 Click on the three dots then click Download 13 Access the downloads folder on your laptop and open the EasyIpSe...

Page 33: ...ork Settings then press Static NOTE If cameras have been powered on for over 20 minutes they will need to be rebooted 18 Do this for each camera 19 Locate the IP address NOTE Make a note of the IP add...

Page 34: ...UI NOTE Do not change any other settings Press Set then Close Click the Live tab and leave open while finishing the camera install 22 Tighten the Pan tilt and yaw the screws to the specified amount i...

Page 35: ...ator rights on the computer in order to install the Supervisor Installing the Software To install the software do the following 1 Locate and double click the file ISSSupervisorSetup_vx x x x exe where...

Page 36: ...u want the files installed in the default location 5 Click Next The following appears Yes No Continue with the next step 1 Click Browse 2 Select the new location 3 Verify the new location appears in t...

Page 37: ...Chapter 4 Software Installation Autoscope IntelliSight User Guide 2022 Image Sensing Systems Inc 4 3 6 Click Next...

Page 38: ...pe IntelliSight User Guide 2022 Image Sensing Systems Inc 4 4 The following appears NOTE If the Visual C Redistributable dependency is not on the computer it will be installed automatically 7 Click In...

Page 39: ...ntelliSight User Guide 2022 Image Sensing Systems Inc 4 5 8 To start the Supervisor automatically after the install is complete select the check box 9 Click Finish to complete the install A shortcut f...

Page 40: ...Supervisor To start the Supervisor software do the following 1 Connect the computer to the IntelliSight Processor using one of the following methods Ethernet cable Plug one end of a CAT5 CAT5e or CAT6...

Page 41: ...e list If devices do not appear in the list click LEARN NETWORK If IntelliSight Processors are connected through a routed network it may be necessary to enter the IP address of the IntelliSight Proces...

Page 42: ...click Program Settings NOTE At present English is the only supported language 2 Select the measurement units for distances English translates all distance measurements into feet Metric translates all...

Page 43: ...Processor to be configured The following appears An image of all setup cameras will appear if the cameras are connected and online one in each of the four quadrants of the image area The order of app...

Page 44: ...the IntelliSight Processor s clock is set by TS2 time set commands from a TS2 compatible controller The IntelliSight Processor monitors the TS2 time every minute and if the difference between the two...

Page 45: ...WAN network interface Primary DNS Address of the primary DNS server Only available for the WAN interface and when Enable DHCP is not selected Secondary DNS Address of the secondary DNS server Only ava...

Page 46: ...lished Configure the device settings Use the camera UI to adjust the zoom and focus if needed Calibrate the camera Add zones stopline advance Assign conditions actions and optionally video overlays to...

Page 47: ...ms Inc 5 8 The following appears 3 In the User Descriptions section enter descriptions for each field as needed The description entered for the first field is what appears as the Device Name in the ot...

Page 48: ...a This can be found by using a third party tool The RSTP Port should be 554 unless specifically changed by the user The RSTP Presentation defines the channel and stream you are trying to connect to Fo...

Page 49: ...e following appears 2 Move the cursor to one of the corner or lane markers then click and drag to the desired location NOTE It is important that the calibration overlay has parallel lines This would n...

Page 50: ...the distance measurements as required by clicking on a value and typing a new one 7 Align the vertical bars with a vertical structure in the image such as a post a pole or the edge of a building If p...

Page 51: ...lapping zones in a configuration is not recommended as this can cause poor detection performance Adding or editing a zone while playing video may cause these operations to appear delayed or jerky Data...

Page 52: ...bration Right Turn Lane two zones appear one for a right turn lane and one covering the remainder of the lanes defined in the calibration Left and Right Turn Lanes two or three zones appear one for a...

Page 53: ...default the vehicle presence condition is selected for each zone In addition green is selected for the zone display color when a vehicle is detected and gray when no vehicle is present in the zone Th...

Page 54: ...apter 5 Configuring IntelliSight Devices Autoscope IntelliSight User Guide 2022 Image Sensing Systems Inc 5 15 Add Zones Manually 1 On the Device screen for the camera click ZONE SETUP 2 Click ADD ZON...

Page 55: ...Inc 5 16 3 Move the cursor to one of the corner markers then click and drag to the desired location The arrows at the corners of the zone can be used to rotate the zone 4 Repeat for each corner until...

Page 56: ...added to the configuration NOTE Because the original zone is probably not a perfect square or rectangle the distance measurement shown for the new zone will be different from the original 7 Adjust the...

Page 57: ...a vehicle is detected and gray when no vehicle is present in the zone There is no default output assigned For each selected condition vehicle and bicycle presence an output must be assigned unless th...

Page 58: ...zone 14 Do you want to add a pedestrian crosswalk zone 15 Do you want to add a pedestrian waiting zone Yes No See Adding an Advance Presence Zone on page 5 20 Continue with the next step Yes No See A...

Page 59: ...operation to appear delayed or jerky 1 On the Zone Setup screen select the Stop Line Zone from which the Advance Zone is to be created Note the width of the Advance Zone will mimic the Stop Line Zone...

Page 60: ...the vehicle presence condition is selected for each zone In addition green is selected for the zone display color when a vehicle is detected and gray when no vehicle is present in the zone There is no...

Page 61: ...er objects should not be in the part of the zone where vehicles would be exiting Receding zones are ideally placed where there is maximum visual separation between vehicles which is usually as close t...

Page 62: ...nd video overlays as required see page 5 26 NOTES By default the vehicle presence condition is selected for each zone In addition green is selected for the zone display color when a vehicle is detecte...

Page 63: ...or to one of the corner markers then click and drag to the desired location 3 Repeat for each corner until the zone covers the crosswalk area 4 To set conditions and actions using Easy Setup see Easy...

Page 64: ...pedestrians are waiting to cross an intersection NOTE Up to two waiting zones can be added 1 On the Zone Setup screen click Add Waiting Zone 2 Move the cursor to one of the corner markers then click a...

Page 65: ...s When selected a bicycle icon appears at the front of zone This condition can be selected in either the Easy Setup or Zones Explorer sections Crossing Pedestrian provides a means of sending an output...

Page 66: ...s check box is used to display overlays on the Zone Setup screen for both static images and video The types of overlays that can be added to a video image are Zone Outline this overlay shows the lines...

Page 67: ...stead of Easy Setup To set conditions and actions using Easy Setup do the following 1 Select a zone either in the image or by clicking the zone description in the Easy Setup section NOTE A presence co...

Page 68: ...plorer section must be used instead of Easy Setup Multiple outputs for a single condition do not appear on the Easy Setup screen To change the initial state of the output or to set the output options...

Page 69: ...n a Crosswalk Zone Assign more than one Set Output action to a single condition Remove Set Output actions from a condition Remove the Display Zone action from a condition Assigning Vehicle or Bicycle...

Page 70: ...for the condition This action is used to define what color the zone is to be outlined in on the video when the presence condition is detected Note it is recommended that red not be used as this is th...

Page 71: ...e delay there is no call to the controller 6 Click the drop down indicator to the left of Vehicle Presence 7 Select or enter the number of seconds to delay 8 To collapse the options box click the arro...

Page 72: ...ical use would be in an Advance zone to determine whether the green phase should be extended NOTE A single zone covering multiple lanes is not recommended when using Pulse outputs 1 In the Zones Explo...

Page 73: ...walk zone has been added in the Zones Explorer section click the plus sign to the right of the zone description and select Pedestrian Crossing Rule 2 Click the drop down menu to define where a pedestr...

Page 74: ...sence Rule The Pedestrian Presence Rule is used to detect when a pedestrian is present in the crosswalk 1 In the Zones Explorer section click the plus sign to the right of the zone description and sel...

Page 75: ...stems Inc 5 36 3 Select or enter the number of seconds to delay The value can be between 0 and 120 seconds Default is 0 4 In the Set Output field select the output that will be sent to the controller...

Page 76: ...and or presence conditions on the video The LED indicator associated with the overlay will light up when the output or condition is activated To use the Actions Explorer do the following 1 Click the A...

Page 77: ...two or more vehicle presence zones share an output see Step 3 To change the pulse width for Pulse conditions see Step 7 3 Do you want to delay the activation of a Vehicle Presence condition 4 Click th...

Page 78: ...lay text will appear on the static image 14 To change the text and appearance of the overlay click on it 15 If any changes are made click APPLY CHANGES Item Description 1 Highlight the text and type w...

Page 79: ...ng Systems Inc 5 40 All assigned outputs are set to call ON and stay in call until detection sets the output OFF or for a maximum of five minutes whichever occurs first After all zones are defined and...

Page 80: ...ed on the camera to the video display Static Text Adds user defined text to the video display To add overlays to the video display do the following 1 Click the VIDEO OVERLAYS heading 2 To add the stan...

Page 81: ...d To move the overlay grab the green circle and place the overlay anywhere on the image 2 Select the size of the font in which the text is to be displayed Default sizes are 44 point Device Name 30 poi...

Page 82: ...ows Condition Descriptions Condition descriptions can be changed in the Zones Explorer and Actions Explorer sections Changes made in one section automatically appear in the other section The default d...

Page 83: ...Click APPLY CHANGES Display Actions Display actions are automatically removed if the zone or condition associated with it is removed 1 In the Zones Explorer or Actions Explorer sections click the X to...

Page 84: ...clears removes the configuration set for a camera view This includes all zone set up information and the camera calibration for the camera To clear a configuration do the following 1 On the Device sc...

Page 85: ...IntelliSight Processor and IntelliSight cameras Figure 6 1 Home Screen To sort the order of devices click on a column heading to sort the devices according to the column information To select multipl...

Page 86: ...through it indicates communications are not established 5 Name of the device as entered in the first User Description field on the Device Settings screen 6 Status information about the device 7 Firmwa...

Page 87: ...ks and the screen and device type for which the operations can be performed Table 6 2 Navigation Section Navigation Link Screen Device Device Info Device IntelliSight Processor IntelliSight Camera Dev...

Page 88: ...tification Settings Camera Setup Camera Calibration and Zone Setup screens Cancel Install Firmware Update Screen see page 6 10 Clear Configuration Device screen see page 5 7 Learn Network Home screen...

Page 89: ...e list 1 On the Home screen click ADD DEVICE BY IP The following appears 2 Enter the network IP address of the WAN port for the IntelliSight Processor to be added to the device list NOTE The address m...

Page 90: ...of the IntelliSight Processor for which the archive file is to be created 2 On the Device screen in the Commands section click SAVE ARCHIVE 3 In the Save Archive window select where the file is to be...

Page 91: ...and select the archive file xxx arch to be opened 3 Click Open A new device appears in the device list on the Home screen Note since this is not a real device the communication icon lightning bolt wil...

Page 92: ...ve file do the following 1 On the Home screen click the icon for the device for which the archive file is to be restored 2 On the Device screen click RESTORE ARCHIVE 3 When the Open window appears loc...

Page 93: ...tions Autoscope IntelliSight User Guide 2022 Image Sensing Systems Inc 6 9 Device Info This function indicates how busy the device is To display the information click Device Info in the Navigation sec...

Page 94: ...pear on the Firmware Update screen 1 In the Commands section of either the Supervisor Home or Device screen click FIRMWARE UPDATE The following appears 2 In the Device Name list select the devices to...

Page 95: ...isightxxx 5 Click Open 6 In the Commands section click START INSTALL NOTE CANCEL INSTALL becomes disabled once the firmware file transfer is completed and the install begins 7 The update is complete w...

Page 96: ...ht of way green yellow change and red clearance intervals in a cycle assigned to various traffic and pedestrian movements through an intersection Failsafe the mode of operation that the IntelliSight C...

Page 97: ...call mode In the case of loss of contrast local contrast and Low Visibility the camera can enter failsafe mode any time day or night When in failsafe mode the outline color of the zones will be red W...

Page 98: ...rst Examples of when failsafe mode may be initiated for a camera include The camera detects a loss of contrast recall options can be set in the Enable Output Options in the Actions Explorer on page 5...

Page 99: ...When doing port forwarding the IntelliSight Processor should be configured with a static IP address that is on the same LAN network as the router cell modem In addition the starting port number in the...

Page 100: ...tting the time on the is determined by the selection for Time Source on the Device Settings screen see IntelliSight Processor Setup on page 5 4 Manual This selection synchronizes the clock in the Inte...

Page 101: ...uch as VLC MPC or MS Media Player uses the device names cam1 cam2 cam3 cam4 or quad to select streaming from IntelliSight Cameras 1 through 4 or the Comm Manger respectively The format for the string...

Page 102: ...ol The bit rate of the video is determined by the Bitrate setting on the Device Settings screen see Camera Device Settings on page 5 7 This control causes live video to be recorded When clicked the Sa...

Page 103: ...tput for each active condition or de select the conditions for each zone Message Invalid setup All set output actions must have an assigned output Leaving will abandon changes Do you wish to leave Des...

Page 104: ...d to reserve Output xx on I O Server yyy because Outputs were not found Go to Zone Setup page to reserve another output Description The indicated output could not be reserved for the camera This is mo...

Page 105: ...started before the IntelliSight Processor or that the IntelliSight Processor is not active If the conflict is not resolved the camera will still do detection however it will not be able to transmit an...

Page 106: ...ocess Device xxxxxxxx yyyyyyyy Do you want to exit anyway Description An attempt is being made to exit the Supervisor however one or more commands yyyyyyyy are still being processed by the Supervisor...

Page 107: ...e is not connected to a routed network or is connected to a network that uses port forwarding which is not supported c The device is not active Suggested Action Do the following 1 Verify that the IP a...

Page 108: ...r Suggested Action Do the following 1 Verify that the cabinet circuit breaker is on and that the power cable is connected to the IntelliSight Processor Symptom IntelliSight Processor Ready LED is red...

Page 109: ...are connected and active Retry the Learn 4 If the problem persists contact Technical Support Symptom Output stays ON Probable Cause This indicates that the camera has gone into failsafe mode see Fail...

Page 110: ...use cleaning solutions with ammonia or alcohol Prepare for cleaning lenses by gathering the following materials A spray bottle with water A spray bottle with a weak solution of dish detergent and wat...

Page 111: ...nt Panel 1 7 Jumper pins 1 10 Rear connector 1 11 Specifications 1 8 Autoscope I O module See Autoscope I O module B Bicycle Differentiation 5 26 Icon 5 26 C Cables Ethernet 2 1 IntelliSight Camera 2...

Page 112: ...ports 1 6 I O module 1 8 IntelliSight Processor 1 6 Power camera 1 6 Logical And Or 5 37 5 38 Loss of contrast 6 14 Luminaire arm 2 3 M Maintenance port 1 5 Mast arm 2 3 Measurement units 5 3 Media Pl...

Page 113: ...5 27 Specifications I O module 1 8 IntelliSight Camera 1 4 Starting the Supervisor 5 1 Stop line presence zone 5 12 Streaming video 6 17 Subnet mask 3 7 5 6 System setup 5 3 T Time Setting 6 16 TS2 t...

Page 114: ...To help us plan future editions of this publication scan the QR code below to answer a few short questions or visit surveymonkey com r QCTFWH2 Autoscope IntelliSight User Guide Feedback...

Reviews: