Chapter 5:
Configuring IntelliSight Devices
Autoscope IntelliSight User Guide
©2022 Image Sensing Systems Inc.
5-33
Assigning a Pulse
Condition
The Pulse condition is used to send an output to the controller every time a
vehicle exits the defined zone. In a system that utilizes a gap timer to extend on
green, the activated (pulsed) output would reset the timer. In a system that
utilizes counts, each exiting vehicle causes a pulse. A typical use would be in an
Advance zone to determine whether the green phase should be extended.
NOTE:
A single zone covering multiple lanes is not recommended when using
Pulse outputs.
1. In the Zones Explorer section, click the plus sign to the right of the zone
description and select
Pulse
.
A Set Output action is automatically added to the Pulse condition.
2. Use the drop-down menu to select an output to be sent to the controller
every time a vehicle exits the zone.
To change the initial state of the output or to set the output options, use the
3. When all conditions and actions have been defined, click
A
PPLY
C