background image

18, Bansong-ro 513Beon-gil, Haeundae-gu, Busan, Republic of Korea, 48002

www.autonics.com  |  +82-51-519-3232  |  [email protected]

-|Transparent Guide|-

Mode

Output operation description in input operation mode
Up / Down - A, B, C

Up / Down - D, E, F

S

RESET

2-stage setting

1-stage setting

0

OUT1

OUT2 (OUT)

RESET

2-stage setting

1-stage setting

0

OUT1

OUT2 (OUT)

OUT1 / 2 maintains ON when counting 

display value ≥ 1 / 2-stage setting value.

OUT1 / 2 maintains ON when counting 

display value ≤ 1 / 2-stage setting value.

Mode

Output operation description in input operation mode
Up

Down

S

RESET

2-stage setting

1-stage setting

0

OUT1

OUT2 (OUT)

RESET

2-stage setting

1-stage setting

0

OUT1

OUT2 (OUT)

OUT1 / 2 maintains ON when counting 

display value ≥ 1 / 2-stage setting value.

OUT1 / 2 maintains ON when counting 

display value ≤ 1 / 2-stage setting value.

Mode

Output operation description in input operation mode
Up, Up / Down - A, B, C

Down, Up / Down - D, E, F

F

RESET

2-stage setting

1-stage setting

0

OUT1

OUT2 (OUT)

RESET

2-stage setting

1-stage setting

0

OUT1

OUT2 (OUT)

After count-up, counting display value increases or decreases until RESET input is applied 

and retained (hold) output is maintained.

N

RESET

2-stage setting

1-stage setting

0

OUT1

OUT2 (OUT)

RESET

2-stage setting

1-stage setting

0

OUT1

OUT2 (OUT)

After count-up, counting display value and retained (hold) output are maintained until 

RESET input is applied.

C

RESET

2-stage setting

1-stage setting

0

OUT1

OUT2 (OUT)

RESET

2-stage setting

1-stage setting

0

OUT1

OUT2 (OUT)

When count-up, counting display value is RESET and it counts simultaneously.

OUT1 retained (hold) output turns OFF after OUT2 One-Shot output time.

• 

One-Shot output time of OUT1 is independent of OUT2 output.

R

RESET

2-stage setting

1-stage setting

0

OUT1

OUT2 (OUT)

RESET

2-stage setting
1-stage setting

0

OUT1

OUT2 (OUT)

After count-up, counting display value is reset after one-shot output time of OUT2 

and it counts simultaneously.

OUT1 retained (hold) output turns OFF after OUT2 One-Shot output time.

• 

One-Shot output time of OUT1 is independent of OUT2 output.

K

RESET

2-stage setting

1-stage setting

0

OUT1

OUT2 (OUT)

RESET

2-stage setting

1-stage setting

0

OUT1

OUT2 (OUT)

After count-up, counting display value increases or decreases until RESET input is applied.

OUT1 retained (hold) output turns OFF after OUT2 One-Shot output time.

• 

One-Shot output time of OUT1 is independent of OUT2 output.

P

RESET

2-stage setting

1-stage setting

0

OUT1

OUT2 (OUT)

RESET

2-stage setting

1-stage setting

0

OUT1

OUT2 (OUT)

After count-up, counting display value is maintained while OUT2 output is ON, and 

internally RESET and it counts simultaneously.

When OUT2 output is OFF, displays counting value while OUT2 output is ON, and it 

increases or decreases.

OUT1 retained (hold) output turns OFF after OUT2 One-Shot output time.

• 

One-Shot output time of OUT1 is independent of OUT2 output.

Q

RESET

2-stage setting

1-stage setting

0

OUT1

OUT2 (OUT)

RESET

2-stage setting

1-stage setting

0

OUT1

OUT2 (OUT)

After count-up, counting display value increases or decreases during One-shot output time 

of OUT2.

OUT1 retained (hold) output turns OFF after OUT2 One-Shot output time.

• 

One-Shot output time of OUT1 is independent of OUT2 output.

  

■ Output operation mode

• 

Output type

Retained (hold) output

OUT1

’ One-shot output (0.5 sec fixed

)

OUT2

 One-shot output

Retained (hold) output

• 

Set OUT2’ One-shot output time via [TIME] volume switch on the front side.

 

setting range: 0.05 to 5 sec

Segment Table

The segments displayed on the product indicate the following meanings. It may differ 
depending on the product.

7 segment

11 segment

12 segment

16 segment

0

0

I

I

0

0

I

I

0

0

I

I

0

0

I

I

1

1

J

J

1

1

J

J

1

1

J

J

1

1

J

J

2

2

K

K

2

2

K

K

2

2

K

K

2

2

K

K

3

3

L

L

3

3

L

L

3

3

L

L

3

3

L

L

4

4

M

M

4

4

M

M

4

4

M

M

4

4

M

M

5

5

N

N

5

5

N

N

5

5

N

N

5

5

N

N

6

6

O

O

6

6

O

O

6

6

O

O

6

6

O

O

7

7

P

P

7

7

P

P

7

7

P

P

7

7

P

P

8

8

Q

Q

8

8

Q

Q

8

8

Q

Q

8

8

Q

Q

9

9

R

R

9

9

R

R

9

9

R

R

9

9

R

R

A

A

S

S

A

A

S

S

A

A

S

S

A

A

S

S

B

B

T

T

B

B

T

T

B

B

T

T

B

B

T

T

C

C

U

U

C

C

U

U

C

C

U

U

C

C

U

U

D

D

V

V

D

D

V

V

D

D

V

V

D

D

V

V

E

E

W

W

E

E

W

W

E

E

W

W

E

E

W

W

F

F

X

X

F

F

X

X

F

F

X

X

F

F

X

X

G

G

Y

Y

G

G

Y

Y

G

G

Y

Y

G

G

Y

Y

H

H

Z

Z

H

H

Z

Z

H

H

Z

Z

H

H

Z

Z

Timer Operation

  

■ Output operation mode

• 

Output type

   

Retained (hold) output

OUT1’ One-shot output (0.5 sec fixed

)

Retained (hold) output

Mode

Output operation description in input operation mode
Up, Up / Down - A, B, C

Down, Up / Down - D, E, F

S

RESET

2-stage setting

1-stage setting

0

OUT1

OUT2 (OUT)

RESET

2-stage setting

1-stage setting

0

OUT1

OUT2 (OUT)

Output turns OFF → ON → OFF repeatedly (flicker).

  

■ Time operation (for indicator model)

Input operation mode = Up, Up / Down - A, B, C Input operation mode = Down, Up / Down - D, E, F

RESET

INHIBIT

+Max. 

display value

0

 

INHIBIT

RESET

+Max.

 display value

-Max. 

display value

0

  

■ Counting operation (for indicator model)

Input operation mode = Up

Input operation mode = Down

RESET

+Max. 

display value

0

 

RESET

+Max. 

display value

-Max. 

display value

0

Input operation mode = Up / Down - A, B, C Input operation mode = Up / Down - D, E, F

RESET

-Max. 

display value

+Max. 

display value

0

RESET

-Max. 

display value

+Max. 

display value

0

Summary of Contents for FXH Series

Page 1: ...r inspect the unit while connected to a power source Failure to follow this instruction may result in fire or electric shock 05 Check Connections before wiring Failure to follow this instruction may result in fire 06 Do not disassemble or modify the unit Failure to follow this instruction may result in fire or electric shock Caution Failure to follow instructions may result in injury or product da...

Page 2: ...ot divided with dot 5959 59 m 59 s SET Divided with dot 0 59 59 59 m 59 s Parameter Display Setting range C1 1 Setting mode DP C1 2 Decimal point setting FX4 4 FX6M 4 FX8M 4 DotforDecimalPoint Hour Min Second If there is no RESET key or DIP switch input for 60 sec it returns to RUN mode RESET key Setting mode RUN mode Move the digit when changing the setting value Decimal point of counter Dot for ...

Page 3: ... phasedifference ON ON ON Down SW1 Output operation mode 7 6 5 Counter Timer OFF OFF OFF F OFF OFF ON N OFF ON OFF C OFF ON ON R ON OFF OFF K ON OFF ON P ON ON OFF Q ON ON ON S S OUT1 One shot output 2 stage setting model SW1 8 OUT1 One shot output ON One shot OFF Hold Timer Time range SW1 Time range 3 2 1 4 digit 6 digit 8 digit OFF OFF OFF 99 99 s 99999 9 s 999999 99 s OFF OFF ON 999 9 s 999999 ...

Page 4: ...CP1 CP2 H H 0 1 1 2 2 2 3 3 L L A A Counting CP1 CP2 H H 0 1 1 2 2 2 3 3 L L A A Up Down B individual input Counting CP1 CP2 H H 0 1 1 1 2 2 2 3 3 L L Counting CP1 CP2 H H 0 1 1 1 2 2 2 3 3 L L Up Down C phase difference input Counting CP1 CP2 H H 0 1 1 2 2 2 3 3 L L 4 B Counting CP1 CP2 H H 0 1 1 2 2 2 3 3 L L 4 B Up countup input Counting CP1 CP2 H H 0 1 2 3 Nocounting 4 5 L L A A Counting CP1 C...

Page 5: ... 1 stage setting 0 OUT1 OUT2 OUT Aftercount up countingdisplayvalueismaintainedwhileOUT2outputisON and internallyRESETanditcountssimultaneously When OUT2 output is OFF displays counting value while OUT2 output is ON and it increases or decreases OUT1 retained hold output turns OFF after OUT2 One Shot output time One Shot output time of OUT1 is independent of OUT2 output Q RESET 2 stage setting 1 s...

Reviews: