background image

-|Transparent Guide|-

DRW161279AD

Digital Counters / Timers

FXM / FXH Series

PRODUCT MANUAL

For your safety, read and follow the considerations written in the instruction 
manual, other manuals and Autonics website.

The specifications, dimensions, etc. are subject to change without notice for product 
improvement. Some models may be discontinued without notice. 

ᜢ ᜧ ᜫ

Features

• 

Counting speeds: 1 cps / 30 cps / 2 kcps / 5 kcps

• 

Switch between counter and timer operation using DIP switch

• 

No-voltage input (NPN) using DIP switch

• 

Operation modes: count-up, count-down, count-up / down

• 

Set decimal point, hr / min / sec display with RESET key

[Counter]

• 

20 input modes, 18 output modes

[Timer]

• 

Various output modes (16 output modes)

• 

Various time setting ranges:

 

- 8-digit models: 0.01 sec to 99999 hr 59.9 min

 

- 6-digit models: 0.1 sec to 99999.9 hr

 

- 4-digit models: 0.01 sec to 9999 hr

• 

Output model types: single preset, dual preset, indicator only

• 

Power supply: 100 - 240 VACᜠ 50 / 60 Hz

Safety Considerations

• 

Observe all ‘Safety Considerations’ for safe and proper operation to avoid hazards.

• 

᜸ symbol indicates caution due to special circumstances in which hazards may occur.

᜸ Warning

  

Failure to follow instructions may result in serious injury or death.

01. 

Fail-safe device must be installed when using the unit with machinery that 

may cause serious injury or substantial economic loss. (e.g. nuclear power 

control, medical equipment, ships, vehicles, railways, aircraft, combustion 

apparatus, safety equipment, crime / disaster prevention devices, etc.)

 

Failure to follow this instruction may result in personal injury, economic loss or fire.

02. 

Do not use the unit in the place where flammable / explosive / corrosive gas, 

humidity, direct sunlight, radiant heat, vibration, impact, or salinity may be 

present.

Failure to follow this instruction may result in explosion or fire.

03. 

Install on a device panel to use.

Failure to follow this instruction may result in fire or electric shock.

04. 

Do not connect, repair, or inspect the unit while connected to a power 

source.

Failure to follow this instruction may result in fire or electric shock.

05. 

Check ‘Connections’ before wiring.

Failure to follow this instruction may result in fire.

06. Do not disassemble or modify the unit.

Failure to follow this instruction may result in fire or electric shock.

᜸ Caution

  

Failure to follow instructions may result in injury or product damage.

01. 

When connecting the power / sensor input and relay output, use AWG 20 

 

(0.50 mm

2

) cable or over, and tighten the terminal screw with a tightening 

torque of 0.74 to 0.90 N m. 

Failure to follow this instruction may result in fire or malfunction due to contact

failure.

02. 

Use the unit within the rated specifications.

Failure to follow this instruction may result in fire or product damage. 

03. 

Use a dry cloth to clean the unit, and do not use water or organic solvent.

Failure to follow this instruction may result in fire or electric shock.

04. 

Keep the product away from metal chip, dust, and wire residue which flow 

into the unit.

Failure to follow this instruction may result in fire or product damage. 

Cautions during Use

• 

Follow instructions in ‘Cautions during Use’. 

 

Otherwise, it may cause unexpected accidents. 

• 

Use the product, 0.1 sec after supplying power.

• 

When supplying or turning off the power, use a switch or etc. to avoid chattering.

• 

Install a power switch or circuit breaker in the easily accessible place for supplying or 

disconnecting the power.

• 

When the counter is operating, in case of contact input, set count speed to low speed 

mode (1 cps or 30 cps) to operate. If set to high speed mode (2 k, 5 kcps) counting 

error occurs due to chattering.

• 

Keep away from high voltage lines or power lines to prevent inductive noise. In case 

installing power line and input signal line closely, use line filter or varistor at power line 

and shielded wire at input signal line.

 

Do not use near the equipment which generates strong magnetic force or high 

frequency noise. 

• 

This unit may be used in the following environments.

 

- Indoors (in the environment condition rated in ‘Specifications’)

 

- Altitude max. 2,000 m

 

- Pollution degree 2

 

- Installation category II

Summary of Contents for FXH Series

Page 1: ...r inspect the unit while connected to a power source Failure to follow this instruction may result in fire or electric shock 05 Check Connections before wiring Failure to follow this instruction may result in fire 06 Do not disassemble or modify the unit Failure to follow this instruction may result in fire or electric shock Caution Failure to follow instructions may result in injury or product da...

Page 2: ...ot divided with dot 5959 59 m 59 s SET Divided with dot 0 59 59 59 m 59 s Parameter Display Setting range C1 1 Setting mode DP C1 2 Decimal point setting FX4 4 FX6M 4 FX8M 4 DotforDecimalPoint Hour Min Second If there is no RESET key or DIP switch input for 60 sec it returns to RUN mode RESET key Setting mode RUN mode Move the digit when changing the setting value Decimal point of counter Dot for ...

Page 3: ... phasedifference ON ON ON Down SW1 Output operation mode 7 6 5 Counter Timer OFF OFF OFF F OFF OFF ON N OFF ON OFF C OFF ON ON R ON OFF OFF K ON OFF ON P ON ON OFF Q ON ON ON S S OUT1 One shot output 2 stage setting model SW1 8 OUT1 One shot output ON One shot OFF Hold Timer Time range SW1 Time range 3 2 1 4 digit 6 digit 8 digit OFF OFF OFF 99 99 s 99999 9 s 999999 99 s OFF OFF ON 999 9 s 999999 ...

Page 4: ...CP1 CP2 H H 0 1 1 2 2 2 3 3 L L A A Counting CP1 CP2 H H 0 1 1 2 2 2 3 3 L L A A Up Down B individual input Counting CP1 CP2 H H 0 1 1 1 2 2 2 3 3 L L Counting CP1 CP2 H H 0 1 1 1 2 2 2 3 3 L L Up Down C phase difference input Counting CP1 CP2 H H 0 1 1 2 2 2 3 3 L L 4 B Counting CP1 CP2 H H 0 1 1 2 2 2 3 3 L L 4 B Up countup input Counting CP1 CP2 H H 0 1 2 3 Nocounting 4 5 L L A A Counting CP1 C...

Page 5: ... 1 stage setting 0 OUT1 OUT2 OUT Aftercount up countingdisplayvalueismaintainedwhileOUT2outputisON and internallyRESETanditcountssimultaneously When OUT2 output is OFF displays counting value while OUT2 output is ON and it increases or decreases OUT1 retained hold output turns OFF after OUT2 One Shot output time One Shot output time of OUT1 is independent of OUT2 output Q RESET 2 stage setting 1 s...

Reviews: