STAIRCASE LIGHTING TIMERy ASH-02
INSTRUCTION MANUAL
ZAMEL
Sp. z o.o.
ul. Zielona 27, 43-200 Pszczyna, Poland
Tel. +48 (32) 210 46 65, Fax +48 (32) 210 80 04
www.zamelcet.com
, e-mail: [email protected]
VER. 004_23.03.2012
APPEARANCE
black
brown
grey
blue
FEATURES
DESCRIPTION
ی Staircase lighting control,
ی Continuous ON-time adjustment of
10 seconds to 14 minutes,
ی Applicable together with single pole
push buttons, illuminated,
ی Counter-interlock function,
ی Either three-conductor or four-con-
ductor wiring system possible,
ی 0.5 m cable terminal,
ی Hermetic IP65 casing,
ی Relay voltage output, 16 A load.
The ASH-02 staircase timer is desi-
gned for corridor and staircase lighting
control. After circuit trigger the timer keeps
the light ON for the preset time and then
switches it OFF. It has an adjustable ON-
time setting of 10 seconds to 14 minutes.
On-time may be adjusted by means of a
potentiometer.
The timer is fitted with a
counter-interlock circuit.
The ASH-02
staircase timer may be applied as a time
relay unit for delayed switch-OFF. The ti-
mer is placed within a hermetic IP65 ca-
sing which assures safe operating under
hard weather conditions.
The device is designed
for single-phase instal-
lation and must be in-
stalled in accordance
with standards valid in
a particular country. The
device should be con-
nected according to the details included
in this operating manual. Installation,
connection and control should be car-
ried out by a qualified electrician staff,
who act in accordance with the servi-
ce manual and the device functions.
Disassembling of the device is equal
with a loss of guarantee and can cause
electric shock. Before installation make
sure the connection cables are not un-
der voltage. The cruciform head screw-
driver 3,5 mm should be used to instal
the device. Improper transport, stora-
ge, and use of the device influence its
wrong functioning. It is not advisable to
instal the device in the following cases:
if any device part is missing or the de-
vice is damaged or deformed. In case
of improper functioning of the device
contact the producer.
CAUTION
TECHNICAL PARAMETERS
ASH-02
Power supply cables: L (black), N (blue)
Input rated voltage: 230 V~
Input voltage tolerance: from -15 to +10 %
Nominal frequency: 50 / 60 Hz
Rated power consumption: 33 mA
Release cable: grey
Output cable: brown
Time adjustment range: from 10 sec to 14 min
Time accuracy adjustment: ±10 %
Time repeatability adjustment: ±5 %
Time adjustment: continuous (rotational potentiometer)
Output relay parameters: 1NO-16 A / 250 V AC1 4000 VA (voltage contact)
Number of switch cables: 4
Section of connecting cables: 4x 1,50 mm
2
Connecting cable length: 0,5 m
Ambient temperature range: from -20 to +45
o
C
Operating position: vertical, pointed down
Mounting: 2x stretcher 5x(3x30)
Protection degree: IP65 (PN-EN 60529)
Protective class: II
Overvoltage category: II
Pollution degree: 2
Dimensions: 69 x 56 x 27 mm
Weight: 0,120 kg
Reference standards: PN-EN 60669-1
PN-EN 60669-2-1
PN-EN 61000-4-2,3,4,5,6,11
Time adjustment
Power supply cable (L)
Power supply cable (N)
Output cable
Release cable