background image

ELETTROMECCANICA CDC S.r.l - TX40

 

- MANUAL rev.2 - PAG.

1

T

X40

DIGITAL ELECTRONIC 

MICROPROCESSOR 

TIMER

MANUAL

 rev.2 11/2021 

ELETTROMECCANICA CDC S.r.l

 

VIA TREVIGLIO 56/58

 

BRIGNANO GERA D'ADDA (BG)

 

TEL. +39 0363 382155

FAX +39 0363 382099

www.cdcelettromeccanica.it

 

[email protected]

PREFACE

D

D

This manual contains the information necessary for
the product to be installed correctly and also instruc-
tions for its maintenance and use; we therefore recom-
mend that the utmost attention is paid to the following 
instructions and to save it.

This document is the exclusive property of 

Elettromeccanica 

CDC

 S.r.l. which forbids any reproduction and divulgation, 

even partially, of the document, unless expressly authorized. 

Elettromeccanica CDC

 S.r.l. reserves the right to make any 

formal or functional changes at any moment and without  any 
notice.

 Elettromeccanica CDC 

S.r.l. and its legal 

representatives do not assume any responsibility for any 
damage to people, things or animals deriving from violation, 
wrong or improper use or in any case not in compliance with 
the instrument features.

D

D

Whenever a failure or a malfunction of the device may

cause dangerous situations for persons, thing or animals, 
please remember that the plant has to be equipped with 
additional devices which will guarantee safety.

1. INSTRUMENT DESCRIPTION

1.1 

General description

T

X40

 is a digital microprocessor timer, it offers the possibility 

to program: 

up to 3 delay times

 (or Set Times), 

5 operating 

modes

 for 

OUT1

 output, 

5 operating modes

 for 

OUT2

 output, 

4 time scales

 (allowing timings from 9999 hours max. to 0.01 

s min.), 

6 counting start modes

 and 

2 counting modes

 (

UP

 

or 

DOWN

).  The timer can also be equipped with an 

internal 

or external buzzer

 for signaling the end of the count.

The 

4 digits display

 normally 

shows

 the 

counting status

 

while the outputs status is signalled by 

2 LEDs

.  The instru-

ment has also 

2 digital inputs

 for voltage-free contacts that 

can be used 

for

 the 

count enabling

 (

CNT EN

) and 

Reset

 

(

RES

) commands and can have 

up to 2 relay outputs

 or 

SSR for driving Solid State Relays

.

The instrument is programmed by using the 3 of the front 
panel keys while the counting commands can be submitted 
using the 

-Start/Stop 

or through the digital inputs 

CNT 

EN

 and 

RES

.  The operating parameters configuration can 

be done through 

keypad

A01

 device connected to 

TTL port

 

(standard) or using 

NFC

 communication (optional).

Index

1. Instrument description ............................................... 1

1.1  General description ........................................................... 1
1.2  Front panel description ..................................................... 2

2. Programming ............................................................... 2

2.1  Fast Set Times programming ............................................ 2
2.2  Standard mode parameters programming ........................ 2
2.3  Parameter protection using a password ............................ 3
2.4  Customized mode parameter programming 

(parameters programming level) ......................................... 3

2.5  Reset parameters to default value .................................... 3
2.6  Keyboard lock function ...................................................... 3

3. Usage warnings ........................................................... 4

3.1  Allowed Usage .................................................................. 4

4. Installation warnings ................................................... 4

4.1  Mechanical Mounting ........................................................ 4
4.2  Mechanical Dimensions [mm] ........................................... 4

4.2.1  Instrument dimensions ......................................................... 4
4.2.2  Panel cutout .......................................................................... 4
4.2.3  Mounting brackets ................................................................ 4

4.3  Electrical connections ....................................................... 4

4.3.1  Electrical connection diagram ............................................... 5

5. Operating mode ........................................................... 5

5.1  Display operation .............................................................. 5
5.2  Operation of the Counting commands .............................. 5
5.3  OUT1 Operating mode ...................................................... 6
5.4  OUT2 Operating mode ...................................................... 7
5.5  Internal buzzer operation .................................................. 8
5.6  Operation in case of power supply failure (backup) .......... 8

6. Accessories ................................................................. 9

6.1  Parameters configuration with A01 ................................... 9
6.2  Parameters configuration with AFC1 ................................ 9

7. Programmable parameters table .............................. 10
8. Problems and maintenance ...................................... 11

8.1 Cleaning .......................................................................... 11
8.2 Disposal .......................................................................... 11

9. Warranty and repairs ................................................. 11
10. Technical data ............................................................ 11

10.1  Electrical data ................................................................. 11
10.2  Mechanical characteristics .............................................. 11
10.3  Functional features ......................................................... 11

11. How to order .............................................................. 12

Summary of Contents for TX40

Page 1: ...r external buzzer for signaling the end of the count The 4 digits display normally shows the counting status while the outputs status is signalled by 2 LEDs The instru ment has also 2 digital inputs for voltage free contacts that can be used for the count enabling CNT EN and Reset RES commands and can have up to 2 relay outputs or SSR for driving Solid State Relays The instrument is programmed by ...

Page 2: ... short key if pressed and released the key has no effect 1 Only s t1 Set Time value can be set with this procedure 2 Only s t2 Set Time value can be set with this procedure 3 s t1 and s t2 Set Times can be set with this procedure 4 Only s t3 Set Time value can be set with this procedure 5 s t1 and s t3 Set Times can be set with this procedure 6 s t2 and s t3 Set Times can be set with this procedur...

Page 3: ... without password unprotected To change the parameter visibility press the key and keeping it pressed press also the button The SET LED changes its state indicating the new level of parameter accessibility ON Not protected Flashing Password protected In case some parameters are set as Not protected access ing the programming mode the display first shows the Not protected parameters then the r p pa...

Page 4: ...To obtain the declared protection degree IP65 use screw type bracket optional Avoid placing the instrument in dirty environments or with very high humidity levels that may create condensation and avoid the introduction of conductive substances into the instrument Ensure adequate ventilation to the instrument and avoid installation in containers that house devices which may overheat or which may ca...

Page 5: ...fore the end steady on Count ended Reset status off After Reset display shows 0000 when counting mode is UP F Cnt uP or Set time value if the count mode is DOWN F Cnt dn While counting display shows the time that elapses increas ing if F Cnt uP or decreasing if F Cnt dn For functions that require a cycle end F o1t 1 2 at the end of the count the display flashes 0000 if F Cnt dn or the Set time val...

Page 6: ...Ft is different from oF only acts as a Reset CNT Count RESET 0 1 2 3 i fct 4 Reset Start Reset Start Stop 0 1 2 3 0 1 2 3 0 Stop Reset i Fct 5 Bistable Reset Start Stop At 1st CNT impulse the timer is reset at the 2nd the count starts at the 3rd impulse the count stops disabling the output if active and so on In this mode the front Start Stop button if t UFt 2 acts in exactly the same way as the C...

Page 7: ...in 5 different modes with F o2t parameter Se si desidera utilizzare OUT2 è possibile stabilirne il funzi onamento tramite il parametro F o2t secondo 5 diversi modi F o2t oF OUT2 Output disabled F o2t 1 OUT2 works like OUT1 OUT2 output operates exactly like OUT1 output in order to have a double output contact F o2t 2 OUT2 output works as an instant contact ON during count OUT2 is activated during t...

Page 8: ...peration The internal buzzer can be programmed using the F buF parameter to operate in the following ways oF Internal buzzer disabled 1 Activated at end of S t1 time for S t2 period sound also when keys are pressed If Reset command is given with key or digital input the buzzer is silenced immediately This mode is only active for operations that normally do not involve the use of the S t2 time this...

Page 9: ...tput operating mode oF No function 1 Out2 operates as Out1 2 Instantaneous Contact Output ON during count 3 Out2 operates as Out1 but with absolute Set time s t3 4 Out2 operates as Out1 but with relative Set time s t3 in advance 5 Out2 operates as the buzzer oF 13 F Cnt Count mode uP UP dn DOWN uP 14 F buF Buzzer operating mode oF Disable 1 Sounds at end of the cycle for the s t2 period key pressu...

Page 10: ...er supply and relay outputs and front panel Reinforced insulation between low voltage parts H or L type power supply and outputs if both are relays and the extra low voltage parts inputs Reinforced insulation between power supply and relay outputs Basic insulation between relay outputs and between relay and SSR drive output Basic insulation between H or L type power supply and inputs when a relay ...

Page 11: ...Codice d ordine T X 4 0 H I R R 1 0 Y Y P ZZ Relè Relay R Statica Static S YY OLP 3RZHU 9DF GF OLP 3RZHU 9DF H Morsettiera estraibile Removable screw terminal M Faston Faston F 0 I Terminali a vite Screw terminal Buzzer With buzzer B No buzzer Not buzzer 0 ...

Reviews: