background image

VER. 004_23.03.2012

CONNECTING

MOUNTING

FUNCTIONING

EXAMPLE OF INSTALLATION

The timer is ready to work just right 

after its appropriate connecting. The light 

will  be  ON  for  the  preset  ON-time  after 

the timer is triggered by means of a single 

pole push button. When the preset time 

is over, the light will be OFF automatical-

ly until the timer is triggered once again. 

The  staircase  timer  may  be  connected 

to either threeconductor or four-conduc-

tor  wiring.  Check  carefully  if  the  trigger 

and  load  circuits  have  been  connected 

correctly. The timer may be damaged if 

connected inappropriately. In case of the 

trigger push button blocking the counter-

interlock circuit switches OFF the light.

1. Disconnect the power supply from the 

mains by the phase fuse, the circuitbre-

aker or the switch-disconnector that are 

joined to the proper circuit.

2. Check if there is no voltage on con-

nection cables by means of a special 

measure equipment.

3. Fasten the ASH-02 to the base with the 

screw.

NOTICE! It is forbidden to bore fitting 

holes in the cover! It may result in the 

loss of containment of the cover and 

by this – the loss of guarantee!

4. Connect  the  cables  ASH-02  with  the 

hermetic installation junction box accor-

ding to installing diagram.

5. Switch  on  the  power  supply  from  the 

mains.

6. Take out the rubber hole plug covering 

the  adjustment  of  the  switch  on  thre-

shold potentiometer.

7. Adjust the demanded switch on time by 

means of a potentiometer.

8. Put back the rubber hole plug covering 

the potentiometer.

DIMENSIONS

INNER DIAGRAM

TIME COURSE

PRODUCT FAMILY

The staircase timer controls the staircase lighting and operates in four-conductor 

wiring configuration. It is possible to connect the single pole push buttons (e.g. illumi-

nated) in parallel.

RELAY CAPACITY

The ASH-02 is a member of the ASx

staircase timer family.

t

t

t

t

t

black

blue

grey

brown

3 wire system

4 wire system

brown

black
blue

grey

brown

brown

black

black

blue

blue

grey

grey

Device version

Casing version:

M -  modular

N -  surface

H -  hermetic

P -  flush junction box Ø60 mm

Device version:

01 -  3- or 4-wire installation

02 -  anti-blocking function

03 -  anti-blocking function and ON/

AUTO/OFF mode switch

10 -  fluent lighting brightening and 

dimming

Voltage version:

24V - 24 V AC/DC 

available for  

ASM-02

    U - 12÷240 V AC/DC 

available for 

ASH-01, ASM-01, ASN-01

Reviews: