7 Counter Mode
50
© Copyright Reserved Autonics Co., Ltd.
Output
mode
Up/Down A, B, C
S [
S
]
※
OUT1 and OUT2 keep ON status in following condition:
Counting display value
≧
PRESET1
Counting display value
≧
PRESET2
T [
T
]
※
OUT1 output is off: Counting display value
≧
PRESET1
(when PRESET 1 is 0, OUT1 output maintains ON state.)
※
OUT2 keeps ON status in following condition:
Counting display value
≧
PRESET2
D [
D
]
※
When counting display value is equal to setting value [PRESET1, PRESET2)
only, OUT1 or OUT2 output keeps ON status.
※
When setting 1kcps for counting speed, solid state contact output should
be used.
(When using contact output, it is difficult to execute normal output operation due
to contact reaction time.)
※
OUT output as 1-stage setting value change model operates as output of OUT 2 as 2-stage
setting value change model.
※
In case of 2-stage setting value change model, OUT1 output operates as as one-shot output or
retained output. (except
S
,
T
,
D
mode)
※
OUT1 output is available to set as ‘0’ at every output mode. The output for ‘0’ setting executes.
※
In case of C[
C
], R[
R
], P[
P
], Q[
Q
] output mode, OUT2 output is not available to set as ‘0’.
Summary of Contents for CT4S-2P series
Page 1: ...Programmable Counter Timer User Manual CT Series CT Series CT Series ...
Page 2: ...내 ii Copyright Reserved Autonics Co Ltd ...
Page 8: ...Cautions During Use 나 viii Copyright Reserved Autonics Co Ltd ...
Page 16: ...1 Product Overview 16 Copyright Reserved Autonics Co Ltd ...
Page 20: ...3 Communication Specification 20 Copyright Reserved Autonics Co Ltd ...
Page 24: ...4 Dimensions 24 Copyright Reserved Autonics Co Ltd ...
Page 36: ...5 Guide For Connection 36 Copyright Reserved Autonics Co Ltd ...
Page 42: ...6 Basic Operations Counter Timer Communication 42 Copyright Reserved Autonics Co Ltd ...