7 Counter Mode
© Copyright Reserved Autonics Co., Ltd.
49
Output
mode
Input mode
Up, Up-1, 2
Down, Down-1, 2
Up/Down A, B, C
K [
K
]
※
After count-up, counting display value increases or decreases until RESET input is
applied.
※
OUT1 retained output is off after OUT2 one-shot time.
※
OUT1 one-shot output time is operated regardless of OUT2 output.
P [
P
]
※
After count-up, counting display value is maintained while OUT2 output is on.
Counting value is internally reset and counts simultaneously.
※
When OUT2 output is off, displays counting value while OUT2 is ON,
and it increases or decreases.
※
OUT1 retained output is off after OUT2 one-shot time.
※
OUT1 one-shot output time is operated regardless of OUT2 output.
Q [
Q
]
※
After count-up, counting display value increases or decreases during OUT2
one-shot time.
※
OUT1 retained output is off after OUT2 one-shot time.
※
OUT1 one-shot output time is operated regardless of OUT2 output.
A [
A
]
.
※
After count-up, counting display value and OUT1 retained output are maintained
until RESET input is applied.
※
OUT1 one-shot output time is operated regardless of OUT2 output.
Summary of Contents for CT4S-2P series
Page 1: ...Programmable Counter Timer User Manual CT Series CT Series CT Series ...
Page 2: ...내 ii Copyright Reserved Autonics Co Ltd ...
Page 8: ...Cautions During Use 나 viii Copyright Reserved Autonics Co Ltd ...
Page 16: ...1 Product Overview 16 Copyright Reserved Autonics Co Ltd ...
Page 20: ...3 Communication Specification 20 Copyright Reserved Autonics Co Ltd ...
Page 24: ...4 Dimensions 24 Copyright Reserved Autonics Co Ltd ...
Page 36: ...5 Guide For Connection 36 Copyright Reserved Autonics Co Ltd ...
Page 42: ...6 Basic Operations Counter Timer Communication 42 Copyright Reserved Autonics Co Ltd ...