![Automationdirect.com GS1-10P2 User Manual Download Page 116](http://html1.mh-extra.com/html/automationdirect-com/gs1-10p2/gs1-10p2_user-manual_3021947116.webp)
Warning Messages
There are several Warning Messages that GS1 AC Drive may give. The GS1 AC
Drive allows you to decide how the AC drive should react to these messages. The
descriptions of the Warning Messages are listed below.
GS1 Series AC Drive User Manual
6–5
Chapter 6: Maintenance and Troubleshooting
Fault Codes
Fault Name Fault Descriptions
Corrective Actions
bb
External Base Block:
AC drive output is turned off.
1. When the external input terminal (base-block) is
active, the AC drive output will be turned off.
2. Disable this connection and the AC drive will begin
to work again.
Warning Messages
Warning
Name
Warning Descriptions
Corrective Actions
Ce0!
Communications Warning:
Illegal command code - The
command code received in the
command message is not
available for the AC drive.
The corrective action can be set with the Transmission
Fault Treatment parameter (9-03). The available settings
are:
0 - Display fault and continue operating
1 - Display fault and RAMP to stop
2 - Display fault and COAST to stop
3 - No fault displayed and continue operating
The default setting is 0.
Ce02
Communications Warning:
Illegal data address - The data
address received in the command
message is not available for the
AC drive.
Ce03
Communications Warning:
Illegal data value - The data value
received in the command
message is not available for the
AC drive.
Ce04
Communications Warning:
Slave device failure - The AC
drive is unable to perform the
requested action.
Ce!0
Communications Warning:
Communication Time Out