DEFAULT
STEP
MAXIMUM
MAXIMUM MOTOR RUN TIME
30 Sec.
_
_
COURTESY LIGHT TIME
3 Min.
10 Sec.
10 Min.
OBSTRUCTION FORCE MARGIN
4
1
16
AUTO CLOSE TIME
0 Sec
5 Sec.
4 Min.
FACTORY SET DEFAULTS
INPUT VOLTAGE:
230 V / 240 V AC 50 Hz
OPENER PUSHING / PULLING
FORCE
300 N
RECEIVER TYPE
UHF 433.92 MHz AM Receiver
Receiver Code Capacity
27 X 4 Transmitter Codes
TRANSMITTER
Frequency
Coding Type
Number of Code Combinations
Code Generation
Battery Voltage
433.92 MHz
Hopping Code
Over 4.29 Billion Hopping Codes
Non-linear Encryption Algorithm
12 Volts
TECHNICAL SPECIFICATION
S
16
DOOR STATUS INDICATORS
.
DOOR OPENER STATE
OPEN LED
GREEN
CLOSE
LED
RED
SERVICE
LED
YELLOW
COURTESY
LIGHT
BEEPER
OPEN
On
CLOSE
On
OPENING
Flashing
CLOSING
Flashing
DOOR TRAVEL STOPPED
Flashing
Flashing
DOOR OBSTRUCTED WHEN OPENING
Flashing
Beeps on and off
DOOR OBSTRUCTED WHEN
CLOSING
Flashing
Beeps on and off
DOOR OVERLOADED
Flashes ten times
Beeps on and off
DOOR AND OPENER REQUIRE A SER-
VICE
Flashing
Beeps at the start of any
cycle
DOOR AND OPENER APPROACHING
OVERLOAD
Beeps for the duration
of the time approaching
overload
DOOR HAS APPROACHED OVERLOAD
THREE TIMES IN EIGHT CYCLES
On
Beeps at the start of any
cycle
DOOR IN OPEN POSITION WITH AUTO
CLOSE MODE SELECTED
One second
flashes
MAINS POWER INTERRUPTED TO
OPENER
Rapid flashes
Summary of Contents for SECURALIFT