31
Instructions for the installer
A
3.22 -
ELECTRICAL CONNECTIONS
Regulations in force
The gas and water feeding pipes and the CH system pipes
cannot be used as ground plates.
Ensure that the above safety electrical requirements subsist;
in case of doubt, ask for a professionally qualified technician
to check the appliance’s electrical system.
UNICAL refuses responsibility for any damages arising from
failure to earth the boiler correctly.
It is necessary that a qualified technician verifies that the
electrical system is adequate to the appliance’s maximum
absorbed power, indicated on the data plate, verifying in
particular that the section of the system’s cables is suitable
to the appliance’s maximum absorbed power.
For the appliance’s general electrical supply the use of
adaptors, multiple sockets and/or extension cords is strictly
forbidden.
The use of any power supplied equipment implies the
observance of several fundamental rules, such as:
-
Do not touch the appliance with any wet part of your body
and/or barefooted;
-
Do not pull the supply cables
-
Do not permit children or inexpert people to use the
appliance.
Mains electrical supply connection 230V
The electric connections of the boiler are shown in the section
named “WIRING DIAGRAMS”
A mains supply of 230 V – 50 Hz is required. The wiring to the
boiler must be in accordance with the current CEI regulations.
WARNING!
We remind you that upstream of the electrical
connection, it will be necessary to foresee a
service relay (NOT SUPPLIED) which, when
the electrical safety devices (ISPESL)
intervene, shuts down the electrical supply
to the on-off fuel valve fitted on the gas supply
circuit, but not to the boiler so as to
guarantee the running of the pump and permit
the boiler to cool down.
DANGER!
The electrical connections must be carried
out only by a qualified engineer.
Before carrying out the connections or any
other operation on the electrical parts,
always switch off and disconnect the
electricity supply and ensure yourself that it
cannot be accidentally turned on.
It is necessary to fit a double pole switch on the electrical
supply line, having a 3 mm contact separation in both poles,
in an easy accessible position in order to make quick and
safe the servicing operations.
The boiler electrical supply (230 V – 50 Hz – single phase) is
to be done directly on the three pole plug supplied with the
boiler.
WARNING!
230 V cables shall be separated from 24 V
ones, using the two plastic conduits supplied
within the boiler casing L.H. side panel.