74
SERVICE DETAILS
11
SECTION
ELEVATING ROOFS
Lifting Mechanism
Gas struts or spring nuts should be checked
for corrosion (particularly on the piston
rods of gas struts), smooth operation when
operating roof up and down and to ensure
that they support the roof when fully up.
Check attachment points of
struts to body and roof.
Canvas Side Walls
Check for satisfactory attachment
to body and roof.
Check for splits or holes,
particularly at fold lines.
Check that the canvas stows satisfactorily
when roof is lowered. (A waterproofing check
will be done at the request of the customer).
Controls
Check that all knobs etc. work smoothly and
are secure on their spindles. If gas taps require
greasing to ease stiffness, use only approved
LPG grease. Check that appliances cab be
brought into service using the normal controls.
Security
Check appliance is securely fixed to the
vehicle/furniture and will be free from rattles.
Where applicable, check that water pipes are
satisfactorily attached with no sign of leakage.
Protection of adjacent surfaces:
Check that surfaces adjacent to open flame
cooking appliance have adequate protection.
Inspections:
It is recommended that inspections
are carried out by a qualified fitter
trained to GAS SAFE standards.
WATER SYSTEM
Before operating the water system, a
visual check of the following items may
show up an obvious leak source:
Fresh Water Tank
Check condition, fill tank and check for leaks.
Check the external filler and filler pipe to tank
Check for satisfactory venting.
Check condition and presence of filler cap.
Waste Water Tank
Check drain tap is clear and working.
Check condition and presence of drain hose.
(The water tank will be drained,
flushed, cleaned and changed with a
measure of toilet fluid/disinfectant at
the prior request of the customer).
System Check
Operate pump. Check all piping for leaks.
Operate taps and shower. If a hot water
system is fitted, it can be checked for
leaks etc., using cold water. (Note: aerated
water from tap could be due to a leak
on the suction side of the pump).
Waste Water System
With water running through the drain
pipes, check for leaks and satisfactory
draining of water from sinks etc.
Couplings and Fluids
Check that the appropriate markings
are used - blue for fresh water, grey
for waste water. Ensure a sealing off
cover is supplied for each coupling.
Check that filler positions are designated
“petrol”, “diesel” or “water” as appropriate.
Summary of Contents for FORD TRANSIT CUSTOM AIR 2022
Page 1: ...FORD TRANSIT CUSTOM AIR OWNER S MANUAL ...
Page 29: ...29 FITTED EQUIPMENT 09 SECTION ...
Page 78: ...78 SERVICE DETAILS 11 SECTION ...
Page 79: ...79 SERVICE DETAILS 11 SECTION ...
Page 80: ...80 SERVICE DETAILS 11 SECTION ...