The following are a series of fault finding charts to which you should refer in the
event of problems you may have regarding 230/12V, LPG and water. This should be
used as a guide only, and in the case of an electrical fault, where a fuse has blown
or an MCB tripped out, the fault must be located before replacing the fuse. If a fault
is suspected with the LPG system, consult a GAS SAFE registered technician.
If in doubt consult a qualified technician or your local Auto-Sleepers dealer.
12V TROUBLESHOOTING CHART
Symptom
Cause
Remedy
Habitation 12V does not
operate
Main 20A fuse blown
Check/Replace
Battery Discharged
Recharge
Switch on control panel in off
position
Switch to on
Vehicle ignition “on”
Switch “off” ignition
Habitation battery not
charging
Main 20A fuse blown
Check/Replace
Relay Fault
Refer to dealer
Contacts dirty/loose on
battery terminals
Clean and check for tightness
Battery does not hold its
charge
Failed battery
Electrically test and replace if necessary
Current being drawn
Check all appliances are off when not in
use
Battery discharges over a
short time with appliances
operating
Poor battery cell condition
Electrically test battery
Failed battery
Change battery
Battery not fully charged
Fully recharge battery
No power to one or more 12V
appliances
Circuit fuse blown
Find fault and replace fuse with same
rating
Water pump not operating
Switch on panel “off”
Switch it “on”
Fuse blown
Find fault and replace fuse with same
rating
No power on 12V socket
outlet
Fuse blown
Find fault and replace fuse with same
rating