69
CARE OF YOUR CAMPERVAN
10
SECTION
LPG TROUBLESHOOTING CHART
Symptom
Cause
Remedy
Appliance will not light
No gas
Check isolation valve is open
Low battery (auto ignition)
Charge battery
Appliance lights but goes
out immediately the FSD
override is released
Flame supervision device
(FSD) is not functioning
correctly
Refer to dealer
Odour
Gas leak
Turn off the gas at the cylinder and do not
use the gas system until the problem has
been rectified.
Open all doors and windows to disperse
any gas escape.
In the event of a leaking cylinder, contact
the site warden and/or the local gas
supplier.
Yellow flame
Lack of primary air, please
note yellow tipping to the
flame is normal
Refer to dealer
Orange flame
Particles of dust or dirt in the
mixing tube being carried
through the burner ports
Reduce the amount of dust in air
Burner ports partially
blocked
Refer to dealer
Floating flame
Lack of secondary air
Check all vents are clear (air inlet to
vehicle)
If in an Oven
Check the flue way is clear