33
mode, and one Help button on the right that you can tap for additional
information.
Each parameter item displays the selected mode independently.
1)
Analog Gauge Mode
– displays the parameters in form of an
analog meter graph.
2)
Text Mode
– this is the default mode
that
displays the parameters
in texts and
displays
in list format.
NOTE
Reading of status parameters, such as a switch reading, which are mostly in
word form,
such as
ON, OFF, ACTIVE, and ABO
R
T
,
can only be displayed
in Text Mode. Whereas reading of value parameters, such as a sensor
reading, can be displayed in text mode and other graph modes.
3)
Waveform Graph Mode
– displays the parameters in waveform
graphs
When this mode is applied, three control buttons will appear on the right
side of the parameter item, allowing you to manipulate the display status.
Text Button
– resumes Text Display Mode.
Scale Button
– changes the scale values, which are displayed
below the waveform graph. There are 4 scales available: x1, x2, x4
and x8.
Zoom-in Button
– tap once to display the selected data graph in full
screen.
Edit Button
– tapping this button opens an edit window, on
which you can set the waveform color and the line thickness
displayed for the selected parameter item.
Scale Button
- changes the scale values, which are displayed
below the waveform graph. There are 4 scales available: x1, x2,
x4 and x8.
Zoom-out Button
– exits full screen display.
4)
Digital Gauge Mode
– displays the parameters in form of a digital
gauge graph.
Full Screen Display
– this option is only available in the waveform graph
mode, and mostly used in Graph Merge status for data comparison.