background image

 

Descripción de componente

s - C

omponents description

2

a. Tuerca superior de fijación de placa.

Top fixing nut of the panel

b. Zonas de rotura, pasa cables.

Wiring breaking zones

c. Apoyo de circuito impreso.

Module of control support

d. Torretas de fijación de circuito impreso.

Fixing little towers of module of control support

e. Engarces del muelle de abatimiento.

Spring joints for panel taking down

f. Tuerca inferior de fijación de placa.

Bottom fixing nut of the panel

Las dimensiones de las cajas de empotrar variarán según el modelo.

The mounting box dimensions will vary depending on model.

Nota: antes de fijar las cajas de empotrar recordar abrir  las zonas de rotura necesarias para el cableado. 

 

Remark: Remind to open the breaking zones necessaries for the wiring before the mounting boxes fixing.

 

b

c

d

e

f

a

b

PLACA DIRECTORIO -

DIRECTORY PANEL

 

CAJA DE EMPOTRAR

/MOUNTING BOX

 

MÓDULO DE CONTROL DIGITAL COMPACT

/MODULE OF CONTROL DIGITAL COMPACT

 

 

c

b

a

d

f

+

Vi

b

Vi

a

V

o

b

a Vo

R

C

ALTAVOZ /

SPEAKER

MICRO/ 

MICROPHONE

RELÉ ABREPUERTAS

DOOR OPENER RELAY

NEGATIVO/

NEGATIVE

SIN CONEXIÓN

NOT CONNECTED

POSITIVO/

POSITIVE

COAXIAL

NO COAX

COAXLESS

Vi

b

Vi

a

Vo

b

a

Vo

ENTRAD

A/

IN

SALID

A/OUT

Vi

b

Vi

a

Vo

b

a

Vo

ENTRAD

A/

IN

SALID

A/OUT

B

+

B-

PULSADOR ABREPUERTAS

DOOR OPENER PUSH-BUTTON

CON7

a.

Bornes de conexión.

Connection terminals

b.

Jumper de configuración.

Configuration jumper

c.

Conector cámara MV-D PT 

camera coaxless connector

d.

Conector módulo de fonía 
y de telecámara.

Audio module and camera 
Connector

e.

Conector iluminación de placa.

Illumination of the panel 
connector (1)

f.

Conector para comprobación  
de monitor

Monitor testing plug

g.

 Conector módulo teclado 

keyboard module connector

h.

 Conector puerto serie 

serial port connector

i.

 Switch de configuración
 

configuration switch

j.

 conectores filas/columnas

        Lines/Columns connector

g

CON3

B

+

+

Vi

b

Vi

a

Vo

b

a

Vo

R

C

CON8

J1

B-

CON6

e

4

3

2

1

ON

i

CON9

CON10

j

CON5

h

Summary of Contents for hi-188

Page 1: ...compact whole range HI 188 compact whole range DIRECTORY PANEL PLACA DIRECTORIO 1 2 3 6 5 4 7 8 9 C 0 auta 10 16...

Page 2: ...fon a j Ajustes de volumen L Ajuste de la orientaci n de telec mara m Conector del m dulo de fon a y telec mara n M dulo LCD o M dulo del teclado p Conector del m dulo teclado LCD profile Audio modul...

Page 3: ...EMPOTRAR MOUNTING BOX M DULO DE CONTROL DIGITAL COMPACT MODULE OF CONTROL DIGITAL COMPACT c b a d f Vi b Vi a Vo b a Vo R C ALTAVOZ SPEAKER MICRO MICROPHONE REL ABREPUERTAS DOOR OPENER RELAY NEGATIVO...

Page 4: ...boxes assembling in the accessory bag to cover the joint zones hollows to avoid the plaster entrance Once the boxes assembled use the self sticking cartoon covers delivered Las placas se sirven con un...

Page 5: ...ESO 1 ACCESS Configurar la placa como principal J1 y c digo 0 Codify the panel like main J1 with code 0 MULTIPLES ACCESOS Configurar un placa acceso principal como principal J1 y c digo 0 y el resto c...

Page 6: ...connector Conectar el m dulo fon a y telec mara en el conector J1 El conector es el mismo para PD digital F y PD digital FV Connect the audio and camera module in the connector J1 The connector is the...

Page 7: ...O STEP 7 PASO STEP 71 PASO STEP 7 2 PLACA DIRECTORIO DIRECTORY PANEL AJUSTE DE LA POSICI N DE LA TELEC MARA Y DEL VOLUMEN DE LA SE AL DE AUDIO ADJUST THE CAMERA POSITION AND THE AUDIO SIGNAL VOLUME so...

Page 8: ...t is also possible to call the guard porter pressing the key 0 and then See the parameter SWITCHBOARD in the Configuration Menu for further information Finally any invalid code will directly perform a...

Page 9: ...s s 1 o r 3 f o r q u i c k s e a r c h At this point it is possible to go forward or backwards among the existing marks pressing 1 and 3 or just navigate register by register with the arrows Remember...

Page 10: ...o SWITCHBOARD This option should be enabled if the installation has a switchboard linked to the Directory panel This means that any call code even a non existing one will make a call to the switchboar...

Page 11: ...ng screens will appear as we press the key in this menu O P E N I N G T I M E 1 5 s e c P A N E L N U M B E R 1 P A N E L i n t e r n a l S E L F S T A R T y e s v 3 0 0 7 0 2 0 8 S W I T C H B O A R...

Page 12: ...ry to fill the data base with a big amount of registers it would be better to use the Remote option described bellow o Auto 5 Pressing 5 we enter the automatic code generation mode The system will ask...

Page 13: ...K button Before erase the register the screen will ask are you sure yes So pressing the key the operation will be confirmed and the register removed To exit this mode press the C key Display Change 3...

Page 14: ...1 1 1 P e d r o 1 A 0 0 0 2 2 2 m t S D L 1 o p e n c o d 0 0 0 0 0 0 m t 1 S D L o p e n c o d 0 0 0 0 0 0 m t 1 S D L o p e n c o d 0 0 0 0 0 0 Again using OK enter the text 1 A Use and OK to write...

Page 15: ...nel must be configured as external in the Configuration Menu because there are two SDLs in the installation connected to the Directory panel X Line Then the Auto mode should be enabled entering the Di...

Page 16: ...ts is high the system will expend a few seconds in the generation of the corresponding registers Press Number of Flats in the first floor of the SDL1 Press 4 Press 4 Number of Flats in the second Floo...

Page 17: ...020102 m t 3 SDL 2 Open Code 000000 Call Code 020103 o FLOOR2 m t 4 SDL 2 Open Code 000000 Call Code 020201 m t 5 SDL 2 Open Code 000000 Call Code 02020210 The fields Name and Flat Info will be the s...

Page 18: ...th a Bluetooth USB antenna connected to a PC or a Laptop or using a bluetooth compatible PDA it is possible to load or transmit the data bases to and from the panel without taking any screw off To lea...

Page 19: ...L MAIN PHONE 1 2 3 J2 JUMPER J1 TELEFONOPRINCIPAL MAIN PHONE 1 2 3 J1 AUX TELEFONO DECOR DIGITAL DECOR PHONE JUMPER J2 TELEFONOPRINCIPAL MAIN PHONE 1 2 3 J2 JUMPER J1 TELEFONOPRINCIPAL MAIN PHONE 1 2...

Page 20: ...NTROL C R Vi b Vi a Vo b Vo a Secciones de hilos Wiring sections Hasta 100 m Up to 100 m R C 1 mm 2 mm 0 5 mm 1 mm Coaxial Tipo Type RG 59 de 75 W Hasta 200 m Up to 200 m QUITAR EL PUENTE EN TODOS LOS...

Page 21: ...VC 4S L S3 S4 L S1 S2 Va Vb LOAD VALUE 150 75 S C LOADED LAST ONE MAIN MONITOR Va Vb MAIN auta VIDEO MONITOR HANDS FREE TFT COLOUR OK LOAD VALUE 150 75 S C LOADED LAST ONE MAIN MONITOR Va Vb Va Vb MAI...

Page 22: ...NTE J2 Para otras configuraciones consultar S n puente monitor PRINCIPAL CONFIGURACION PUENTE J1 Consult about other kind of configurations MONITOR COMPACT DIGITAL PT MONITOR COMPACT DIGITAL PT MONITO...

Page 23: ...os de la l nea van polarizados Polarized lines J1 position 1 2 self starting ON J1 position 2 3 self starting OFF CONFIGURATION JUMPER J2 Without jumper MAIN monitor CONFIGURATION JUMPER J1 J1 posici...

Page 24: ...N ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1...

Page 25: ...POL IND EL OLIVERAL CALLE C NAVES 9 10 46394 RIBARROJA DEL TURIA VALENCIA TFNO 34 96 164 30 20 FAX 34 96 166 52 86 E MAIL AUTA AUTA ES HTTP WWW AUTA ES...