background image

     

 

      PLACA DIRECTORIO 

– DIGITAL PANEL DIRECTORY 

 

 

 

 

 

9

Funcionamiento

-

Functioning

Configuration Menu (C+

+Configuration Menu Code (‘1’)+

 
 

 

This menu has been created to set the following 7 Panel Parameters: 

 

o

 

OPENING CODE

. 4 different common “Opening Codes” up to 6 digits, to be assigned to the 

postman or to the doorman, but not usually to the neighbours of the building. By default these 
codes are 

101010, 202020, 303030, and 404040. If these codes are all of them set with the 

value ‘0’, the common opening code function will be disabled. 

 

o

 

OPENING TIME

. 2 different configurable “Opening Times”. The first one will be used 

when the user is outside the building

2

 and the second one if the user is inside the building 

(pressing the hall-button inside the building. This opening time is usually longer). By default 
the 

Time1=5 seconds

 and the 

Time2 = 8 s

. (Max Time for both = 9 seconds). 

 

o

 

PANEL NUMBER

. There are not dip-switches any more to set the panel number. Now it is 

configured with the keypad. By default, it will be set to 

1

. The system allows to connect til 15 

different panels. Be careful not to put the same panel number in multiple accesses installation. 

 

o

 

PANEL internal / external. 

The Panel should be configured as ‘

external

’ if it performs the 

call through an SDL (connected to the X (external) line of the SDL), otherwise the Panel will 
be configured as ‘

internal

’. From the v2.0, the screen will also show the software version and 

an internal identification code. 

 

o

 

SELF STARTING

. The self-starting can be enabled or disabled in this menu. 

 

o

 

SWITCHBOARD

. This option should be enabled if the installation has a switchboard linked 

to the Directory panel. This means that any call code (even a non existing one) will make a 
call to the switchboard. If this option is configured as ‘

SWITCHBOARD: no

’ there is still 

the possibility to assign the call code ‘0’ to a telephone / monitor that will work as if it was a 
switchboard. The non existing codes introduced in the panel, will also be redirected to this 
telephone / monitor. If the installation needn’t switchboard functions, it is recommended to 
set ‘

SWITCHBOARD: no

’ and be sure not having any call code ‘0’ in the data base.

3

 

 

o

 

NEW ACCESS CODE

.  It is strongly recommended to change the codes of the 

Configuration & Directory menus. Keep in mind that these codes were, by default, ‘

1

’ and ‘

9

’ 

respectively. To change them just enter the new code and confirm it with 

OK

.

 

 

 

To navigate through the parameters the 

 

key should be used. To change through the different 

options inside each parameter use the arrows (

Å

Æ

) and the 

OK 

key to confirm the changes. 

Any numerical parameter can be changed directly with the numeric keypad, and confirmed with 
the 

OK 

(a beep should be heard). To exit this menu, simply press the 

key once. 

 
 

Configuration Menu Screens 

 
 

 

When an authorized installer press 

C

 and then 

, the following screen appears waiting for a code: 

 
 

   

 

 

 

 

 

 

 

 

 

 

   

 

 

   

 

 

  

      

 

 

 

 

 

 

 

 

 

 

                                                 

2

 That is when we call to a flat and someone opens the door, also when we introduce our personal ‘

Opening Code

’ or a 

general ‘

Opening Code

’. 

3

 If there is a guard porter button in the installation and it is pressed: If ‘

SWITCHBOARD: yes

’ it will make a call to the 

guard porter, if ‘

SWITCHBOARD: no

’ it will call the telephone / monitor with the ‘

call code

’ 0 only if it exists in the DB.

 

Press C+

 

Summary of Contents for hi-188

Page 1: ...compact whole range HI 188 compact whole range DIRECTORY PANEL PLACA DIRECTORIO 1 2 3 6 5 4 7 8 9 C 0 auta 10 16...

Page 2: ...fon a j Ajustes de volumen L Ajuste de la orientaci n de telec mara m Conector del m dulo de fon a y telec mara n M dulo LCD o M dulo del teclado p Conector del m dulo teclado LCD profile Audio modul...

Page 3: ...EMPOTRAR MOUNTING BOX M DULO DE CONTROL DIGITAL COMPACT MODULE OF CONTROL DIGITAL COMPACT c b a d f Vi b Vi a Vo b a Vo R C ALTAVOZ SPEAKER MICRO MICROPHONE REL ABREPUERTAS DOOR OPENER RELAY NEGATIVO...

Page 4: ...boxes assembling in the accessory bag to cover the joint zones hollows to avoid the plaster entrance Once the boxes assembled use the self sticking cartoon covers delivered Las placas se sirven con un...

Page 5: ...ESO 1 ACCESS Configurar la placa como principal J1 y c digo 0 Codify the panel like main J1 with code 0 MULTIPLES ACCESOS Configurar un placa acceso principal como principal J1 y c digo 0 y el resto c...

Page 6: ...connector Conectar el m dulo fon a y telec mara en el conector J1 El conector es el mismo para PD digital F y PD digital FV Connect the audio and camera module in the connector J1 The connector is the...

Page 7: ...O STEP 7 PASO STEP 71 PASO STEP 7 2 PLACA DIRECTORIO DIRECTORY PANEL AJUSTE DE LA POSICI N DE LA TELEC MARA Y DEL VOLUMEN DE LA SE AL DE AUDIO ADJUST THE CAMERA POSITION AND THE AUDIO SIGNAL VOLUME so...

Page 8: ...t is also possible to call the guard porter pressing the key 0 and then See the parameter SWITCHBOARD in the Configuration Menu for further information Finally any invalid code will directly perform a...

Page 9: ...s s 1 o r 3 f o r q u i c k s e a r c h At this point it is possible to go forward or backwards among the existing marks pressing 1 and 3 or just navigate register by register with the arrows Remember...

Page 10: ...o SWITCHBOARD This option should be enabled if the installation has a switchboard linked to the Directory panel This means that any call code even a non existing one will make a call to the switchboar...

Page 11: ...ng screens will appear as we press the key in this menu O P E N I N G T I M E 1 5 s e c P A N E L N U M B E R 1 P A N E L i n t e r n a l S E L F S T A R T y e s v 3 0 0 7 0 2 0 8 S W I T C H B O A R...

Page 12: ...ry to fill the data base with a big amount of registers it would be better to use the Remote option described bellow o Auto 5 Pressing 5 we enter the automatic code generation mode The system will ask...

Page 13: ...K button Before erase the register the screen will ask are you sure yes So pressing the key the operation will be confirmed and the register removed To exit this mode press the C key Display Change 3...

Page 14: ...1 1 1 P e d r o 1 A 0 0 0 2 2 2 m t S D L 1 o p e n c o d 0 0 0 0 0 0 m t 1 S D L o p e n c o d 0 0 0 0 0 0 m t 1 S D L o p e n c o d 0 0 0 0 0 0 Again using OK enter the text 1 A Use and OK to write...

Page 15: ...nel must be configured as external in the Configuration Menu because there are two SDLs in the installation connected to the Directory panel X Line Then the Auto mode should be enabled entering the Di...

Page 16: ...ts is high the system will expend a few seconds in the generation of the corresponding registers Press Number of Flats in the first floor of the SDL1 Press 4 Press 4 Number of Flats in the second Floo...

Page 17: ...020102 m t 3 SDL 2 Open Code 000000 Call Code 020103 o FLOOR2 m t 4 SDL 2 Open Code 000000 Call Code 020201 m t 5 SDL 2 Open Code 000000 Call Code 02020210 The fields Name and Flat Info will be the s...

Page 18: ...th a Bluetooth USB antenna connected to a PC or a Laptop or using a bluetooth compatible PDA it is possible to load or transmit the data bases to and from the panel without taking any screw off To lea...

Page 19: ...L MAIN PHONE 1 2 3 J2 JUMPER J1 TELEFONOPRINCIPAL MAIN PHONE 1 2 3 J1 AUX TELEFONO DECOR DIGITAL DECOR PHONE JUMPER J2 TELEFONOPRINCIPAL MAIN PHONE 1 2 3 J2 JUMPER J1 TELEFONOPRINCIPAL MAIN PHONE 1 2...

Page 20: ...NTROL C R Vi b Vi a Vo b Vo a Secciones de hilos Wiring sections Hasta 100 m Up to 100 m R C 1 mm 2 mm 0 5 mm 1 mm Coaxial Tipo Type RG 59 de 75 W Hasta 200 m Up to 200 m QUITAR EL PUENTE EN TODOS LOS...

Page 21: ...VC 4S L S3 S4 L S1 S2 Va Vb LOAD VALUE 150 75 S C LOADED LAST ONE MAIN MONITOR Va Vb MAIN auta VIDEO MONITOR HANDS FREE TFT COLOUR OK LOAD VALUE 150 75 S C LOADED LAST ONE MAIN MONITOR Va Vb Va Vb MAI...

Page 22: ...NTE J2 Para otras configuraciones consultar S n puente monitor PRINCIPAL CONFIGURACION PUENTE J1 Consult about other kind of configurations MONITOR COMPACT DIGITAL PT MONITOR COMPACT DIGITAL PT MONITO...

Page 23: ...os de la l nea van polarizados Polarized lines J1 position 1 2 self starting ON J1 position 2 3 self starting OFF CONFIGURATION JUMPER J2 Without jumper MAIN monitor CONFIGURATION JUMPER J1 J1 posici...

Page 24: ...N ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1...

Page 25: ...POL IND EL OLIVERAL CALLE C NAVES 9 10 46394 RIBARROJA DEL TURIA VALENCIA TFNO 34 96 164 30 20 FAX 34 96 166 52 86 E MAIL AUTA AUTA ES HTTP WWW AUTA ES...

Reviews: