5 | Technical data
EN
Operating manual Fireplace inserts S3
26
6
Specification mg/m³ for heated filter method (in compliance with Annexe III, number 4, letter a, sec-
tion i, point 1) or g/kg for measurement in dilution tunnel (in compliance with Annexe III, number 4, let-
ter a, section i, point 2 and 3.)
7
Specifications are made here for the preferred fuel only.
5.2
General specifications
Model
48x51x51
S3
48x72x51
S3
64x33x51
S3
75x35x45
S3
Vuur
Drie
60
Vuur
Drie
80
EN test EN 13229
CE mark
Nominal heat efficiency in [kW]
10
15
10
10
12
15
Maximum heat output [kW]
15
18
15
15
16
18
Max. length of firewood
33
33
33
33
33
33
permissible fuel filling quantity [Kg]
3.2
3.8
3.2
3.2
3.4
3.8
Fuel throughput, maximum [kg/h]
3.03
4.62
3.02
3.00
3.67
4.31
Cross-section, convection outlet [cm²]
720
720
700
718
696
700
Cross-section, convection inlet [cm²]
710
710
700
706
696
700
Power output via pane [%]
--
--
--
--
--
--
Emissions values
48x51x51
S3
48x72x51
S3
64x33x51
S3
75x35x45
S3
Vuur
Drie
60
Vuur
Drie
80
CO [mg/Nm³]
≤1250
≤1250
≤1250
≤1250
≤1250
≤1250
Dust based on 13% O2
≤40
≤40
≤40
≤40
≤40
≤40
OGC [mg/MJ]
≤50
≤50
≤50
≤50
≤50
≤50
NOx based on 13% O2[mg/m³]
≤150
≤150
≤150
≤150
≤150
≤150
Efficiency [%]
≥80
≥80
≥80
≥80
≥80
≥80
Flue gas temperature [°C]
***)
231
270
261
263
254
276
Flue gas mass flow [g/s]
11.96
17.32
11.86
11.49
11.4
14.8
Minimum feed pressure at nominal heat
output [Pa]
12
12
12
12
12
13
Distances from fireplace insert
48x51x51
S3
48x72x51
S3
64x33x51
S3
75x35x45
S3
Vuur
Drie
60
Vuur
Drie
80
Distances from fireplace insert to heating
chamber wall [cm]
6
Specifications for fire- and heat protection (specifications in mm, Promasil 950 KS) Insulation layer thicknesses
48x51x51
S3
48x72x51
S3
64x33x51
S3
75x35x45
S3
Vuur
Drie
60
Vuur
Drie
80
Insulation layer thicknesses at installation
base [mm]
-
-
-
-
-
-
Insulation layer thicknesses, lateral / rear
[mm]
-/60
-/60
-/60
-/60
-/60
-/60
Insulation layer thicknesses at ceiling
[mm]
in accordance with the normal regional standards (e.g. TR OL, FeuVo)