19
DigiPageM16
INSTALLATION SERIES
Australian Monitor
Installation and Setup
The CAT5 cable connects to the RJ45 socket on the rear panel of the paging station. This
socket is a NEUTRIK
connector designed to be used with the XLR style housing (model
NE8MC) to improve reliability. Normal RJ45 connectors can also be used.
Plugging and unplugging the cable while the system is powered up may result in the system
locking up and is not recommended. If this should happen, reset the DigiPage by switching
off, then on.
To accommodate different speech levels, there is a gain control on the base of the
DigiPageM. This ships set to minimum and may be adjusted to suit. Increasing this control
too far may cause the paging station to distort if loud or close speech levels are
encountered.
In an RS485 network (of which the DigiPage is part of) it is important to terminate the last
device in the network CAT5 RUN. Two jumpers are provided for the data transmission and
the voice transmission to be terminated if that Paging Station is at the end of a CAT5 RUN
(see diagram).Shipped as terminated.
TM
6 GAIN
7 TERMINATING
When making changes be sure to power off the system and disconnect from the network.
Note: these stations are not compatible with the DigiPageJr network system.
7
Voice
Data
(shown as terminated)
Gain Pot
(accessible through base plate)