15
NOTE: A full discussion of setting up a complex system with correct gain structure is
beyond the scope of this manual. The procedure above assumes that the
installer has correctly set up external equipment connected to Digipage proir
to initiating the set up procedure.
INSTALLATION SERIES
Australian Monitor
5. Do a test page in the TEST ZONE and check the level relative to the program level.
6. Adjust the page level as desired [front panel PAGE].
7. Set the input level type of any local inputs being used [rear panel LOCAL MIC/LINE].
8. Select and check the local inputs in each zone.
Adjust the local level as desired [front panel LOCAL].
9. Balance the other program sources in the TEST ZONE [rear panel PROG GAIN]
10.Apply the front panel settings from TEST ZONE to all other zones.
11.Using the front panel controls only set the individual zones to your preferred settings
a. Set balance between local/prog/page
b. Set Eq
c. Set final master level
Troubleshooting Guide
Mains brownouts or incorrect
connection of devices may
cause processor to lock-up
Incorrect system gain
structure
Lack of system ground
Initailisation (boot) sequence
Cable too long
Cable fault
Station lock-up due to
connection while system is live
Actually controlling a different
zone
Cable fault
Another device has control of
the zone
Busy LED on
Busy LED never blinks
No effect:busy LED blinks
Emits high-pitch whine
Inconsistent operation
LED’s chase
No response to controls
Poor signal to noise ratio
Cycle power on the DigiPage
-Check settings of all equipment
-Revisit Step-by-Step Setup Procedure
Normal operation when power
is applied
See Installation section
-Check cable.
-Check Paging Station with good cable at DigiPage
With all Paging Stations connected,
cycle power on the DigiPage
Program correctly
(factory setting is zone 1)
-Check cable
-Check Remote Panel with good cable at DigiPage
-Check other units
-Cycle power if suspect system lock-up
See Grounding in Installation
section
DigiPage System
Likely Cause
Remedy
Trouble
Paging Station
Remote Control Panel
All Call works but
Zone Page does not
Main unit set to slave
Set main unit master/slave switch
to master (switch in)