21
Installation
The CAT5 cable connects to the screw terminals numbered 1-6. These numbers correspond
to the pins of the RJ45 connector on the main unit. If following the 568A convention, the wire
colours are wired as
PIN1
GROUND
green/white
PIN2
+18V
green
PIN3
Data+
orange/white
PIN4
-Busy
blue
PIN5
+Busy(+18V)
blue/white
Ensure that the spare pair cannot short to anything.
There are two holes available adjacent to the terminal block for securing the CAT5 cable with
a cable tie.
PIN6
Data-
orange
PIN7
Spare
brown/white
PIN8
Spare
brown
6298
-A
1
2
3
4
5
6
INSTALLATION SERIES
Australian Monitor
Programming
The following steps are for programming the remote control panel for use in ZONE X:
1. Hold down the RESET button on the back.
2. While holding down the RESET button, hold down both the Up and Down volume buttons.
3. Release the RESET button.
4. The remote control panel will beep 3 times indicating it is in program mode. The BUSY LED
will stay lit while in program mode.
5. Press the Up button X times (the unit will beep each time). Eg. for ZONE 4, press 4 times
6. Press the Down button.
7. The BUSY LED will go out. The remote control panel is now programmed.
8. Confirm that the panel is controlling the correct zone.
4. Busy
5. Volume Up/Down
6. Terminating
This LED lights when the system network is busy. The remote control panel is disabled while the
system is busy unless it is the panel in use generating the busy indication.
These two buttons increase or decrease the volume within the zone.
In an RS485 network (of which the DigiPage is part of) it is important to terminate the last
device in the network CAT5 RUN. A jumper is provided for the data transmission to be
terminated if that Remote Control Panel is at the end of a CAT5 RUN. Shipped as terminated.
NOTE:
If the Remote Control Panel is NOT the last unit in the CAT5 RUN and there
are paging stations connected further down the run it is important that
the spare pair is continued to the next unit otherwise voice information
from the paging stations will not get to the main DigiPage unit.