Check and verify that flue pipe connection to the appliance when using single 40mm
flue pipe and co-axial flue pipe installation is correctly installed and secured in line
with instruction in the Installation Manual Pages 9-16.
Prior to operating the appliance check for dust or glass particles lying on top of the
burners.
Check and verify that decorative glass is placed correctly as per instructions on Page
19 of this Installation Manual. If decorative glass is incorrectly positioned or placed
wrongly it can create a hazardous situation, and in most instances, the heater will not
operate correctly.
For your personal safety, check and verify that polarities are correct in the power
supply to the heater. Also check for proper earth connections at the power source. If
polarities in power supply are incorrect, change the polarities in the power supply to
heater, NOT in the heater cord. Incorrect polarity’s will cause the appliance not to
function correctly.
Check and verify prior to starting up the appliance, that all panels are secured in
place and that the main door has been locked in position.
After verifying and checking all the above points, proceed to lighting instructions.
Refer page 27-29.
25