10
FLUEING OPTIONS INSTALLATION
For applications refer pages 10-11-12 of this Installation Manual.
CO-AXIAL FLUE KIT FOR ARCHER GAS LOG SPACE HEATER
Notes:
1/
When connecting 40mm Ø and 65mm Ø flue pipe to item the co-axial manifold starter
and item 4 co-axial cowl, do not glue flue pipe connections to allow for removal of flue
pipe for servicing the heater.
2/
When connecting 40mm pipe at adaptor end and at cowl end, ensure that 40mm pipe
is long enough to fit securely at both ends. Failure to do so will cause the flames to go
out and the heater will operate incorrectly.
3/
The flue terminal must be fixed in position on the external surface of the building with a silicone
bead. To remove the flue terminal for service, etc. cut the silicone bead with a safety blade.
No.
Description
Qty
1
Co
-
Axial Manifold Starter (factory fitted)
1
2
Ø40mm PVC Pipe
400mm
3
Ø65mm PVC Pipe
400mm
4
Co
-
Axial Flue cowl
1
Approx.
Summary of Contents for Archer IS720G