Aura Cebilon User Manual Download Page 8

8

Membrane Filter (349004Z)

 is the place where the reverse osmosis occurs. 

A long film made of a semi-permeable material is wrapped  onto a reel in two 

layers.  These two layers are merged together with a separator between the 

edges of this film with two layers and it is closed to water passage. It is like a 

closed long narrow bag except its end wrapped on the reel with rowed holes 

that is on the end which allows clean water output only. This double layer 

film is wrapped onto a reel.  Through the separator film placed between the 

windings, dirty  water reaches  all surfaces of this bag, clean water enters the 

bag under pressure and taken from  the outlet holes. While dirty water passes 

by the film surfaces with a flow called cross-flow, a part of water passes through 

the internal part of the film as clean water (Figure 3).

High Pressure Switch** 

stops the pump when the pressure of the tank  filled 

with  clean water reaches 2.6 bar (38 psi).

Clean Water Tank

 inner surface is coated with a "food contact" plastic  material  

suitable for food and enables clean water to be stored in a hygienic environment. 

Tank Valve controls the water inlet and outlet to/from the tank. 

Mineral Carbon Filter (340005Z06)

 provides mineral to the clean water collected 

in  tanks or directly from the membrane  before if flows from  the faucet, enriches 

the  water and regulates the pH. THROTTLE ensures formation of required pressure 

in  the membrane  by restricting flow so that the membrane can perform the 

separation process. It is located on the line where the waste water is drained.

Clean Water Faucet

 is where clean water is taken. 

Pump Adapter**

 is the power supply of the pump, it converts the mains 

voltage to  24 V DC.

Fields of Use

Solenoid Valve*

 

controls the flow of water. When the water pressure in the tank 

reaches a certain value, it closes the water inlet and prevents water being consumed 

unnecessarily.

Digital Display*

 

is used for tracking the life of each filter based on the water passed 

throug the filters. When the filter life is over, the water is cut or in case of a water

leakage it alerts the user.

Flow meter*

 

is used in determining the amount of water passing through the filters 

and monitoring the current flow rate.

Water Leakage Sensor*

 detects water leakage and blocks the water inlet of the system.

Water Leakage Shut off

 Closes the water inlet mechanically in case of water leakage.

* Applicable for 101 ME model.

** Applicable for 101 ME and 101 MD models.

*** Applicable for 101 MD and 101 FG models.

This appliance is used to obtain drinking water from the mains water that have 

passed through the municipal treatment processes. This water should be microbio-

logically safe, subjected to the necessary disinfection.

If the parameters of the water are within the following ranges efficient operation 

of the appliance is ensured. Systems designed differently for waters such as sea 

water, well water, muddy water etc. with a very high TDS value are also available.

40 psi-145 psi / (2,8 bar-10 bar) / (275 kPa - 1.000 kPa)

3-11

MAXIMUM FE

0,2 (ppm=mg/L)

MAXIMUM TDS

1250 (ppm=mg/L)

5 NTU

5

˚

C - 38 

˚

C / (38 

˚

F - 100 

˚

F)  

TEMPERATURE

OPERATING PRESSURE

PH RANGE

TURBIDITY

17

˚

Fr-10 

˚

dH - 170 mg/L CaCO3

HARDNESS

# Max. pressure matches the structural integrity test value of NSF/ANSI Standard 58 for 101ME model

Summary of Contents for Cebilon

Page 1: ...101ME Tested and Certified by NSF International NSF ANSI Standard 58 for the Reduction Claims Specified on the Performans Data Sheet DIGITAL WITH PUMP WITH OUT PUMP User Manual...

Page 2: ...lease read the entire user manual carefully and keep it as a reference Dear Customer Our manual contains information about the technical and hardware features of three di erent models The appliance yo...

Page 3: ...E FAUCET REVERSE OSMOSIS RO WATER PURIFICATION SYSTEMS WASTE WATER CONNECTION PRE TESTS POINTS FOR ATTENTION MAINTENANCE FILTER REPLACEMENT PERFORMANCE DATA SHEET FILTER REPLACEMENT PERIODS CEBILON PA...

Page 4: ...trations while the water molecules pass through the pores the solid particles with a large size cannot pass Since there are more water molecules in the water with low concentration and as a result mor...

Page 5: ...rane pre ltration processes such as sediment lter carbon lter are carried out to retain the coarse residues and the chlorine used in the water disinfection Components such as these lters used before a...

Page 6: ...6 8 6 Parts and Functions Figure 2 RO System Diagram Abwasser Waste Water A Cable Connection Colours White Adapter B Red Solenoid Valve C Green Pump D Yellow Low Pressure Switch E Blue High Pressure S...

Page 7: ...the water clear Automatic Shut o Valve controls the ow of water If the system continues to run after the tank is full the water is wasted as a waste This is an undesirable condition Water should be cu...

Page 8: ...the waste water is drained Clean Water Faucet is where clean water is taken Pump Adapter is the power supply of the pump it converts the mains voltage to 24 V DC Fields of Use Solenoid Valve controls...

Page 9: ...ce s tank capacity is 8 litres approximately 2 2 gallons BOX SIZE mm 580x277x450 8 L 100 psi 689 kPa TANK CAPACITY 6 7 psi 40 48 kPa AIR TANK PRESSURE 75 15 gpd 284 47 L day DAILY CAPACITY 85 98 PURIF...

Page 10: ...form protective membrane solution Install the tube that has flow restrictor on it but not to install the tube that goes to post carbon filter Allow water flow for 2 3 minutes to clear the membrane sol...

Page 11: ...sser Waste Water 11 8 2 7 6 3 4 5 1 Figure 4 RO Installation Diagram 1 Cebilon 2 Water Inlet Valve 3 Appliance Water Inlet 4 Waste Water Outlet 5 RO Water Outlet Clean Water 6 24 V Input 7 Waste Water...

Page 12: ...0 mm diameter bore bit Bore bit is attached to the end of the drill and it is set to low speed Water is poured on the ground to be drilled do not drill without water Bend the bore bit as 45 degrees an...

Page 13: ...1 ME and 101 MD models only If waste water pipe of the sink is not a throat hose but a 40 mm plastic pipe it is mounted in a 3 8 clamp sealing sponge a xed state Figure 7a The ush is drilled from the...

Page 14: ...r 101 ME model After the lter replacement process is nished the ball valve is opened respectively When water starts to come from the faucet tank valve opens and the faucet is closed Warning Performanc...

Page 15: ...for 101ME model Tagesvolumen Daily Capacity 75 15gpd 284 47 L day Leistungsrate E ciency Rate 30 93 R ckgewinnungsrate Recycling Rate Arbeitsdruck Operating Pressure min max Arbeitstemp i Operating T...

Page 16: ...l Valve 1 4 24 351011Z Front Cover 9 351022Z Upper Body Panel 25 356004Z Solenoid Valve 10 351005Z Digital Display Cover 26 346002Z High Pressure Switch 11 356001Z Digital Display 27 346001Z Low Press...

Page 17: ...he appliance eliminate bendings if any Please consult the service Please consult the service This is not a fault Decrease in clean water is normal during winter Please consult the service Insu cient a...

Page 18: ...e of GAC lter in gallon As water passes through the appliance the value decreases Figure 11d 3 MODE Shows the life of the 1 micron sediment lter in gallon As water passes through the appliance the val...

Page 19: ...19...

Page 20: ...Value SERVICE TELEPHONE PRODUCTSERIALNO Signature Service Personnel Name Surname TDSAfter Filter Replacement TDSBefore Filter Replacement REPLACEDFILTERS Order No FilterReplacement DatePRODUCT SERIALN...

Page 21: ...WaterTUSValue SERVICE TELEPHONE PRODUCTSERIALNO Signature Service Personnel Name Surname TDSAfter Filter Replacement TDSBefore Filter Replacement REPLACEDFILTERS Order No FilterReplacement DatePRODUCT...

Page 22: ...or the adapter of the appliance 11 Have you checked the chlorine in the membrane inlet after installation 12 Have you checked clean water waste water ratio 13 Have you selected the throttle based on t...

Page 23: ...transmitted to the collection points for recycling the electrical and electronic appliances If you dispose of this product correctly you will be contributing to the protection of the nature and human...

Page 24: ...Sitesi 7 Cad No 14 Beylikd z stanbul Tel 0212 875 35 62 Faks 0212 875 36 64 www iea com tr info iea com tr TDF 583 358015ZEN FOR INFORMATION AND SUPPORT SERVICES Name of the Distributor Company Telep...

Reviews: