Figure 9 a
Figure 9 b
Figure 9 c
Figure 9 d
Figure 9 e
Substance
Total dissolved
solids (TDS)
750
± 40
770
30
96.0%
187
Influent Challenge
Concentration
Average
Influence
(mg/L)
Average
Effluent
(mg/L)
Average %
Reduction
Maximum permissible
product water
concentration (mg/L)
Maintenance of your appliance must be
performed by an Authorized Service,
appliances that of the maintenance is not
performed by an Authorized Service
will fall out of warranty.
The life of the filters used in Aura Cebilon
Reverse Osmosis System changes depending
on various factors with the amount of water
used. These major factors are inlet water
quality, chlorine amount, residue amount
etc. Filters are considered as supplies and
they are out of warranty.
Maintenance
Filter Replacement
• Pull the front cover towards yourself.
(Figure 9a)
•
The filter to be replaced is lifted up 30
degrees. (Figure 9b). Then, it is turned to
left 90 degrees and removed (Figure 9c).
•
The new filter is fitted by turning 90
degreesto the right (Figure 9d). Then, it is
lowereddown 30 degrees to its former
location.(Figure 9e)
•
The front cover is fitted back.
The ball valve and the tank valve in the
appliance are closed respectively before
the filter replacement. The pressure in
the system is removed by opening the
faucet of the appliance. Filter
replacement is carried out after the E0
error appears on the screen and after
the alarm sounds. (for 101 ME model)
After the filter replacement process is
finished, the ball valve is opened
respectively. When water starts to
come from the faucet, tank valve
opens and the faucet is closed.
Warning
Performance
Data Sheet
101ME model system conform to NSF/ANSI
58 for the specific performance claims as
verified and substantiated b test data.
• Do not use this system with any water that
is microbiologically unsafe, that does not
have adequate disinfection before or after
operation or that of the quality is unknown.
• Aura Cebilon Reverse Osmosis System
contains critical components that are
required to be replaced periodically to purify
the total dissolved solid materials (TDS). To
check the efficiency of the system, water
from the appliance must be tested
periodically.
• Your appliance contains critical
components that must be replaced
periodically with respect to the system's
efficiency. These critical components must be
replaced with components and filters with
the specifications defined by the
manufacturer so that the system can operate
continuously with the same efficiency and
performance.
Filter must not be replaced when inlet
water is open and without removing
the pressure in the appliance.
101ME has been sested according to
NSF/ANSI 58 for reduction of substances
listed below. The concentration of the
indicated substances in botter entering
the system was reduced to a concentration
less than or equal to the permessible limit
for water leaving the system, as specified
in
NSF/ANSI 58. Testing was performed under
standard laboratory conditions, actual
performance vary.
14
Summary of Contents for Cebilon
Page 19: ...19...