Aura Cebilon User Manual Download Page 12

12

Water Connection

•  Close the mains water from the apartment inlet valve.
•  After draining the water left in the pipes from proper places,  mount the three-way 

adapter to the mains by ensuring the sealing.
• 

First, mount the 1/4 ball valve to the three-way adapter by wrapping   a teflon tape in a 

position so that the valve is opened and closed easily   (Figure 5.a).
•  Connect the water inlet hose to the ball valve (Figure 5.b).
•  Make sure the ball valve is closed (Figure 5.c).
•  Open the mains water, check whether there is any leakage (Figure 5.d).
•  Place the appliance on a suitable place underneath the counter in upright position.

Figure 5. Water connection fittings

Installing the faucet

Clean water faucet should be mounted carefully in terms of use  and aesthetics. If the counter or kitchen sink will be 

drilled, drilling process should be proceeded after the  dimensions are obtained so  as to install the washers, nuts and 

unions under the counter or kitchen sink (Figure 6).  Otherwise, drillingmay be incorrect.

The location to be drilled may be granite, marble, concrete or stainless  sink. If the counter is granite, it must be drilled 

with a 20 mm diameter  bore bit. Bore bit is attached to the end of the drill and it is set to low  speed. Water is poured 

on the ground to be drilled (do not drill  without water). Bend the bore bit as 45 degrees and press slightly,  it makes 

a trail on the granite. Then it is brought to an upright position slowly without lifting. When it reaches the upright position, 

drilling iscompleted by applying enough force. If the bore bit is not kept  constant when we start drilling, parts can break 

off from the granite surface. The o-ring on the faucet's mirror cannot ensure sealing and  may cause the water leakage 

down from the counter. Marble  countertops can be drilled by the same drilling bit or bore bit. Concrete countertops 

are drilled with a contact tip and hammer drill. If concrete is coated with tiles, a pre drill is made with a small-diameter  

drill bit to avoid cracking the tiles. Bore bit for the stainless sinks is different.

The hose should be mounted carefully between the faucet mounted  

on the counter and on the appliance where "Clean Water" is written.

Figure 6. Faucet

13  Faucet Screw
14  1/4” Hose

12  Compression Nut

11  Crinkled Spring Washer

9  Mounting Plastic 
10  Plastic Mounting Washer

7  Body Bushing O-ring
8  Mounting Parts

6  Body Bushing 

5  Faucet Body

4  Hub Cover

3  Opening/Closing Handle

2  Upper Body Part

1  Faucet Pipe

b

d

c

a

Summary of Contents for Cebilon

Page 1: ...101ME Tested and Certified by NSF International NSF ANSI Standard 58 for the Reduction Claims Specified on the Performans Data Sheet DIGITAL WITH PUMP WITH OUT PUMP User Manual...

Page 2: ...lease read the entire user manual carefully and keep it as a reference Dear Customer Our manual contains information about the technical and hardware features of three di erent models The appliance yo...

Page 3: ...E FAUCET REVERSE OSMOSIS RO WATER PURIFICATION SYSTEMS WASTE WATER CONNECTION PRE TESTS POINTS FOR ATTENTION MAINTENANCE FILTER REPLACEMENT PERFORMANCE DATA SHEET FILTER REPLACEMENT PERIODS CEBILON PA...

Page 4: ...trations while the water molecules pass through the pores the solid particles with a large size cannot pass Since there are more water molecules in the water with low concentration and as a result mor...

Page 5: ...rane pre ltration processes such as sediment lter carbon lter are carried out to retain the coarse residues and the chlorine used in the water disinfection Components such as these lters used before a...

Page 6: ...6 8 6 Parts and Functions Figure 2 RO System Diagram Abwasser Waste Water A Cable Connection Colours White Adapter B Red Solenoid Valve C Green Pump D Yellow Low Pressure Switch E Blue High Pressure S...

Page 7: ...the water clear Automatic Shut o Valve controls the ow of water If the system continues to run after the tank is full the water is wasted as a waste This is an undesirable condition Water should be cu...

Page 8: ...the waste water is drained Clean Water Faucet is where clean water is taken Pump Adapter is the power supply of the pump it converts the mains voltage to 24 V DC Fields of Use Solenoid Valve controls...

Page 9: ...ce s tank capacity is 8 litres approximately 2 2 gallons BOX SIZE mm 580x277x450 8 L 100 psi 689 kPa TANK CAPACITY 6 7 psi 40 48 kPa AIR TANK PRESSURE 75 15 gpd 284 47 L day DAILY CAPACITY 85 98 PURIF...

Page 10: ...form protective membrane solution Install the tube that has flow restrictor on it but not to install the tube that goes to post carbon filter Allow water flow for 2 3 minutes to clear the membrane sol...

Page 11: ...sser Waste Water 11 8 2 7 6 3 4 5 1 Figure 4 RO Installation Diagram 1 Cebilon 2 Water Inlet Valve 3 Appliance Water Inlet 4 Waste Water Outlet 5 RO Water Outlet Clean Water 6 24 V Input 7 Waste Water...

Page 12: ...0 mm diameter bore bit Bore bit is attached to the end of the drill and it is set to low speed Water is poured on the ground to be drilled do not drill without water Bend the bore bit as 45 degrees an...

Page 13: ...1 ME and 101 MD models only If waste water pipe of the sink is not a throat hose but a 40 mm plastic pipe it is mounted in a 3 8 clamp sealing sponge a xed state Figure 7a The ush is drilled from the...

Page 14: ...r 101 ME model After the lter replacement process is nished the ball valve is opened respectively When water starts to come from the faucet tank valve opens and the faucet is closed Warning Performanc...

Page 15: ...for 101ME model Tagesvolumen Daily Capacity 75 15gpd 284 47 L day Leistungsrate E ciency Rate 30 93 R ckgewinnungsrate Recycling Rate Arbeitsdruck Operating Pressure min max Arbeitstemp i Operating T...

Page 16: ...l Valve 1 4 24 351011Z Front Cover 9 351022Z Upper Body Panel 25 356004Z Solenoid Valve 10 351005Z Digital Display Cover 26 346002Z High Pressure Switch 11 356001Z Digital Display 27 346001Z Low Press...

Page 17: ...he appliance eliminate bendings if any Please consult the service Please consult the service This is not a fault Decrease in clean water is normal during winter Please consult the service Insu cient a...

Page 18: ...e of GAC lter in gallon As water passes through the appliance the value decreases Figure 11d 3 MODE Shows the life of the 1 micron sediment lter in gallon As water passes through the appliance the val...

Page 19: ...19...

Page 20: ...Value SERVICE TELEPHONE PRODUCTSERIALNO Signature Service Personnel Name Surname TDSAfter Filter Replacement TDSBefore Filter Replacement REPLACEDFILTERS Order No FilterReplacement DatePRODUCT SERIALN...

Page 21: ...WaterTUSValue SERVICE TELEPHONE PRODUCTSERIALNO Signature Service Personnel Name Surname TDSAfter Filter Replacement TDSBefore Filter Replacement REPLACEDFILTERS Order No FilterReplacement DatePRODUCT...

Page 22: ...or the adapter of the appliance 11 Have you checked the chlorine in the membrane inlet after installation 12 Have you checked clean water waste water ratio 13 Have you selected the throttle based on t...

Page 23: ...transmitted to the collection points for recycling the electrical and electronic appliances If you dispose of this product correctly you will be contributing to the protection of the nature and human...

Page 24: ...Sitesi 7 Cad No 14 Beylikd z stanbul Tel 0212 875 35 62 Faks 0212 875 36 64 www iea com tr info iea com tr TDF 583 358015ZEN FOR INFORMATION AND SUPPORT SERVICES Name of the Distributor Company Telep...

Reviews: