Have timely periodic maintenance of your appliance to use your system efficiently

and for longer time. The following replacement periods are the recommended 

durations for appliances used in mains water under  normal conditions. The usage  

condition of your appliance may change depending on the properties of inlet water, 

amount of chlorine and sediment.

Our authorized services will perform periodic maintenance required for your system to 

work efficiently every six months.

Recommended Filter 

Replacement Periods

! Daily capacity, efficiency rating and recovery raiting for 101ME model 

Efficiency rating means the percentage of the influent water to the system that is 

available to the user as reverse osmosis treated water under operating conditions that 

approximate typical daily usage.

** Recovery rating means the percentage of the influent water to the membrane 

portion of the system that is available to the user as reverse osmosis treated water 

when the system is operated without a storage tank or when the storage tank is 

bypassed

# Max. pressure matches the structural integrity test value of NSF/ANSI Standard 58 for 101ME model

Tagesvolumen / Daily Capacity 

75.15 gpd (284.47 L/day)

Leistungsrat

e  / Efficiency Rate(

*) 

30.93%

Rückgewinnungsrate / Recycling Rate (**)
Arbeitsdruck  / Operating Pressure (min-max)
Arbeitstemp. i 

ı / Operating Temperature (min

-max)

pH-Bereich / Ph Range 

3-11

Maximum Fe (Eisen) / Maximum Fe (Iron)
Maximum TDS  / Maximum TDS

1250 (ppm=mg/L)

Trübheit / Turbidity

5 NTU

Härte / Hardness 

17 °Fr-10 °dH -170 mg/LCaC03

34.89%
40-145psi / 2.8-10 bar / 275-1.000 kPa

5-38°C/38-100°F

0,2 (ppm=mg/L)

Filter Name

5M Sediment Filter 

Carbon Filter

Mebrane 

Part Code

Duties

350003Z

350004Z

349004Z

350002Z

340005Z06

Mineral Carbon Filter

Replacement Period

Months or 1500 Galons

Months or 3000 Galons

6-12 

Months or 3000 Galons

6-12 

Months or 3000 Galons

6-12 

Years or 6000 Galons

2-5 

Sediment filtration is performed by taking coarse particles in water. Clears the water at a micron level. Its life varies depending on the nature of the inlet water.

Keeps all the gas in water chemically in itself. The excess chlorine reduces the life of the carbon filter. Timely replacement protects from damage of chlorine and extends the life of the membrane filter. 

Regulates the pH by supplying mineral to water.

This is where Reverse Osmosis occurs. Life of the filter will change depending on the ion concentration in the mains water, amount of the distilled water and whether the maintenance is carried out in a timely manner.

1M Sediment Filter Carbon Filter 

This filtration is performed by taking coarse particles in water. Clears the water at a micron level. Its life varies depending on the nature of the inlet water.

Summary of Contents for Cebilon

Page 1: ...101ME Tested and Certified by NSF International NSF ANSI Standard 58 for the Reduction Claims Specified on the Performans Data Sheet DIGITAL WITH PUMP WITH OUT PUMP User Manual...

Page 2: ...lease read the entire user manual carefully and keep it as a reference Dear Customer Our manual contains information about the technical and hardware features of three di erent models The appliance yo...

Page 3: ...E FAUCET REVERSE OSMOSIS RO WATER PURIFICATION SYSTEMS WASTE WATER CONNECTION PRE TESTS POINTS FOR ATTENTION MAINTENANCE FILTER REPLACEMENT PERFORMANCE DATA SHEET FILTER REPLACEMENT PERIODS CEBILON PA...

Page 4: ...trations while the water molecules pass through the pores the solid particles with a large size cannot pass Since there are more water molecules in the water with low concentration and as a result mor...

Page 5: ...rane pre ltration processes such as sediment lter carbon lter are carried out to retain the coarse residues and the chlorine used in the water disinfection Components such as these lters used before a...

Page 6: ...6 8 6 Parts and Functions Figure 2 RO System Diagram Abwasser Waste Water A Cable Connection Colours White Adapter B Red Solenoid Valve C Green Pump D Yellow Low Pressure Switch E Blue High Pressure S...

Page 7: ...the water clear Automatic Shut o Valve controls the ow of water If the system continues to run after the tank is full the water is wasted as a waste This is an undesirable condition Water should be cu...

Page 8: ...the waste water is drained Clean Water Faucet is where clean water is taken Pump Adapter is the power supply of the pump it converts the mains voltage to 24 V DC Fields of Use Solenoid Valve controls...

Page 9: ...ce s tank capacity is 8 litres approximately 2 2 gallons BOX SIZE mm 580x277x450 8 L 100 psi 689 kPa TANK CAPACITY 6 7 psi 40 48 kPa AIR TANK PRESSURE 75 15 gpd 284 47 L day DAILY CAPACITY 85 98 PURIF...

Page 10: ...form protective membrane solution Install the tube that has flow restrictor on it but not to install the tube that goes to post carbon filter Allow water flow for 2 3 minutes to clear the membrane sol...

Page 11: ...sser Waste Water 11 8 2 7 6 3 4 5 1 Figure 4 RO Installation Diagram 1 Cebilon 2 Water Inlet Valve 3 Appliance Water Inlet 4 Waste Water Outlet 5 RO Water Outlet Clean Water 6 24 V Input 7 Waste Water...

Page 12: ...0 mm diameter bore bit Bore bit is attached to the end of the drill and it is set to low speed Water is poured on the ground to be drilled do not drill without water Bend the bore bit as 45 degrees an...

Page 13: ...1 ME and 101 MD models only If waste water pipe of the sink is not a throat hose but a 40 mm plastic pipe it is mounted in a 3 8 clamp sealing sponge a xed state Figure 7a The ush is drilled from the...

Page 14: ...r 101 ME model After the lter replacement process is nished the ball valve is opened respectively When water starts to come from the faucet tank valve opens and the faucet is closed Warning Performanc...

Page 15: ...for 101ME model Tagesvolumen Daily Capacity 75 15gpd 284 47 L day Leistungsrate E ciency Rate 30 93 R ckgewinnungsrate Recycling Rate Arbeitsdruck Operating Pressure min max Arbeitstemp i Operating T...

Page 16: ...l Valve 1 4 24 351011Z Front Cover 9 351022Z Upper Body Panel 25 356004Z Solenoid Valve 10 351005Z Digital Display Cover 26 346002Z High Pressure Switch 11 356001Z Digital Display 27 346001Z Low Press...

Page 17: ...he appliance eliminate bendings if any Please consult the service Please consult the service This is not a fault Decrease in clean water is normal during winter Please consult the service Insu cient a...

Page 18: ...e of GAC lter in gallon As water passes through the appliance the value decreases Figure 11d 3 MODE Shows the life of the 1 micron sediment lter in gallon As water passes through the appliance the val...

Page 19: ...19...

Page 20: ...Value SERVICE TELEPHONE PRODUCTSERIALNO Signature Service Personnel Name Surname TDSAfter Filter Replacement TDSBefore Filter Replacement REPLACEDFILTERS Order No FilterReplacement DatePRODUCT SERIALN...

Page 21: ...WaterTUSValue SERVICE TELEPHONE PRODUCTSERIALNO Signature Service Personnel Name Surname TDSAfter Filter Replacement TDSBefore Filter Replacement REPLACEDFILTERS Order No FilterReplacement DatePRODUCT...

Page 22: ...or the adapter of the appliance 11 Have you checked the chlorine in the membrane inlet after installation 12 Have you checked clean water waste water ratio 13 Have you selected the throttle based on t...

Page 23: ...transmitted to the collection points for recycling the electrical and electronic appliances If you dispose of this product correctly you will be contributing to the protection of the nature and human...

Page 24: ...Sitesi 7 Cad No 14 Beylikd z stanbul Tel 0212 875 35 62 Faks 0212 875 36 64 www iea com tr info iea com tr TDF 583 358015ZEN FOR INFORMATION AND SUPPORT SERVICES Name of the Distributor Company Telep...

Reviews: