AUKS Light CAC R22 60Hz T3 Controller
39
Ventilation operation
1.Start the air conditioner by depressing the ON/OFF button;
2.Depress the MODE button to select VENTILATION mode;
3.Depress air speed button to select between “Auto→ Low speed
→ Middle speed→ High speed”;
4.Stop the air conditioner by depressing the ON/OFF button
again.
Note: Setting temperature is not possible under VENTILATION
mode and there will be no temperature display.
1.Timer ON operation
①
With the air conditioner and remote control off, press the timing button, the display screen of the remote
control will display
“Timer ON”, with the time and time range displayed in the number zone:
(0.5-24)hours
;
②
Depress set button to adjust the time by 0.5 hour per
depressing before 10 hours and 1 hour per depressing
afterward, to the desired time;
③
Depress the timing button again to set the function of
“Timer ON”.
④
Depress other function buttons to set the operation
condition after the starting of the air conditioner
(including mode, temperature, air damper, air speed,
etc.), the display screen will display and hold all your
settings until the set time is reached , then the air
conditioner will start and run under preset conditions.
2.Timer OFF operation
①
With the air conditioner and remote control on, press
the timing button, the display screen of the remote
control will display
“Timer OFF”, with the time and
time range displayed in the number zone: (0.5-24)hours
;
②
Depress set button to adjust the time by 0.5 hour per
depressing before 10 hours and 1 hour per depressing
afterward, to the desired time;
③
Depress the timing button again to set the function of
“Timer OFF”.
3.Cancellation of the timing function
With the air conditioner under timing mode, depressing timing button or ON/OFF button will cancel the
timing mode.
Summary of Contents for AFC-1000CF/4
Page 1: ...1 Technical Manual Fan Coil Unit Ceiling Floor Type...
Page 3: ...AUKS Fan CoilGeneral description 3 Part 1 General description 1 Nomenclature...
Page 15: ...AUKS Fan CoilUnit information 15 5 Electrical wiring and connection...
Page 22: ...AUKS Fan CoilUnit information 22 7 Explode view AFC 400CF 4 AFC 500CF 4...
Page 30: ...AUKS Fan CoilUnit information 30...
Page 53: ...Service Manual 53 6 Failure analysis Wired controller communication failure...
Page 54: ...Service Manual 54 Drainage system failure...
Page 55: ...Service Manual 55 No action after power on...
Page 56: ...Service Manual 56 Poor Performance during Unit Operation...
Page 57: ...Service Manual 57...
Page 58: ...Service Manual 58 Abnormal sound or vibration...
Page 59: ...Service Manual 59 Abnormal odor...
Page 60: ...Service Manual 60 Air conditioner water leakage...