Installation
COMpact 4000 - Instructions V05 10/2018
47
• ISDN telephones in accordance with the Euro ISDN Standard (DSS1)
• ISDN PC controllers in accordance with the Euro ISDN Standard (DSS1)
Important:
For COMfortel 1400/2600 with answering machine: In order to ensure that the
full scope of functions is available, you should connect only 1 telephone per port.
Requirements:
• Enabled operating mode “S
0
internal“ at the S
0
port in question
• Enabled terminators in the PBX at the internal S
0
port in question (exception: bus wiring in
two directions)
If PBX and terminal have a
short distance to each other,
make the connection with an
ISDN cable (max. 10 m) at the
RJ-45 sockets of the internal S
0
port.
If the distance between PBX
and terminal is greater, lay the
lines fixed at the terminal
clamps of the internal S
0
port.
ISDN Terminal at the Internal U
P0
Port
Connection possibilities:
• System telephones COMfortel 1200/1400/1600/2600 (firmware version 1.6A or later)
• ISDN telephones in accordance with the Euro ISDN Standard (DSS1)
• ISDN PC controllers in accordance with the Euro ISDN Standard (DSS1)
operating mode “S
0
internal“
terminators enabled
internal S
0
port
IAE/UAE8
terminators
100 Ohm, 0.25 W
Summary of Contents for COMpact 4000
Page 77: ...COMpact 4000 V05 10 2018 77 2 5 mm...
Page 78: ...78 COMpact 4000 V05 10 2018 14 6 EMVG DECT...
Page 79: ...COMpact 4000 V05 10 2018 79 PIN IP wireshark NAT www bsi bund de TK Anlagen COMpact 4000...
Page 80: ...80 COMpact 4000 V05 10 2018 230 VAC 10 50 Hz 0 5 A I 6 W 48 W 0 40 20 70 10 90...
Page 87: ...COMpact 4000 V05 10 2018 87 3 1 2 2 5 mm...
Page 89: ...COMpact 4000 V05 10 2018 89 3 2 5 mm2 1 2 3...
Page 90: ...90 COMpact 4000 V05 10 2018 COMpact 2BRI 1 2 1 2 1 2 Ethernet Interface COMpact 4000...
Page 91: ...COMpact 4000 V05 10 2018 91 Ethernet 1 2 230 V LED Status LED Power LED LED Power...
Page 95: ...COMpact 4000 V05 10 2018 95 3 10 m J Y St Y 2 x 2 x 0 6 ISDN...