Commissioning
38
COMpact 4000 - Instructions V05 10/2018
• Only a fixed installation is allowed for the connection of the earthing terminal of the PBX
to the potential compensation bar of the house installation or the protective earth
conductor. Plug connections are not allowed.
Requirements:
• Screw driver
• Connecting cable with at least 2.5 mm
²
conductor cross-section
• Proper earth connection close to the installation site (equipotential bonding rail of the
house installation or protective earth conductor)
• No terminal devices connected
1. Connect the connecting cable to the potential
compensation bar of the house installation or the
protective earth conductor.
2. Insert the connecting cable into the casing and
connect it to the earth terminal.
Updating or Upgrading the PBX
Warning:
Touching voltage-carrying conductors or telephone connections can
cause life-threatening electric shocks. The PBX contains hazardous voltages, even
outside of the power supply unit (for instance ringer voltages). Work on active,
contact-hazardous parts is only permitted after creating a voltage-free state. Working close
to active parts is only permitted if these parts are voltage-free or are protected against
direct contact.
• Pull out the PBX's power plug. Also disconnect the device from additional power sources
(e. g. UPS, if installed).
• Wait at least 3 minutes for the discharge of any capacitor in the device after
disconnecting it from the main power supply.
Caution:
Electrostatic charges can destroy sensitive components.
•Discharge electrostatic charges from yourself before touching the circuit boards
with your hands or any tools. To do this, touch a preferably earthed metal object, such
as the PBX's earthing terminal or a computer case.
Important:
Before you insert a COMpact 2BRI module, first make the necessary port
settings on the module (operating modes and terminators).
Inserting a Module
1. Slide the module into the board guides with the
component side pointing to the left.
2. Press the module upward until the board lock
clicks into place.
Summary of Contents for COMpact 4000
Page 77: ...COMpact 4000 V05 10 2018 77 2 5 mm...
Page 78: ...78 COMpact 4000 V05 10 2018 14 6 EMVG DECT...
Page 79: ...COMpact 4000 V05 10 2018 79 PIN IP wireshark NAT www bsi bund de TK Anlagen COMpact 4000...
Page 80: ...80 COMpact 4000 V05 10 2018 230 VAC 10 50 Hz 0 5 A I 6 W 48 W 0 40 20 70 10 90...
Page 87: ...COMpact 4000 V05 10 2018 87 3 1 2 2 5 mm...
Page 89: ...COMpact 4000 V05 10 2018 89 3 2 5 mm2 1 2 3...
Page 90: ...90 COMpact 4000 V05 10 2018 COMpact 2BRI 1 2 1 2 1 2 Ethernet Interface COMpact 4000...
Page 91: ...COMpact 4000 V05 10 2018 91 Ethernet 1 2 230 V LED Status LED Power LED LED Power...