Commissioning
COMpact 4000 - Instructions V05 10/2018
39
Removing a Module
1. Unlatch the board lock, for example with your
right thumb.
2. Remove the module with your other hand.
Connecting the PC
Requirements:
• Available network socket on the PC or
in the network of the PC
1. Insert one end of the accompanying
network cable into the network socket
on the PC or in the network of the PC.
2. Insert the other end of the network
cable into the Ethernet socket on the
COMpact 4000 interface board.
Closing the Casing
Important:
Before closing the casing, secure the Ethernet cable
with a cable tie to one of the straps provided for strain relief.
Note:
The connections for the first commissioning (connection to a
PC/network and, if necessary, connection of a few terminals) must
be made before the casing is closed. Alternatively, you can
prepare them by laying a connecting cable that leads out of the
housing.
Requirements:
• Cables carefully reinserted into
the cable space after installation
1. Place the upper edge of the
cover onto the top of the
casing.
2. Press the lower edge of the
cover against the casing until it
clicks into place.
Summary of Contents for COMpact 4000
Page 77: ...COMpact 4000 V05 10 2018 77 2 5 mm...
Page 78: ...78 COMpact 4000 V05 10 2018 14 6 EMVG DECT...
Page 79: ...COMpact 4000 V05 10 2018 79 PIN IP wireshark NAT www bsi bund de TK Anlagen COMpact 4000...
Page 80: ...80 COMpact 4000 V05 10 2018 230 VAC 10 50 Hz 0 5 A I 6 W 48 W 0 40 20 70 10 90...
Page 87: ...COMpact 4000 V05 10 2018 87 3 1 2 2 5 mm...
Page 89: ...COMpact 4000 V05 10 2018 89 3 2 5 mm2 1 2 3...
Page 90: ...90 COMpact 4000 V05 10 2018 COMpact 2BRI 1 2 1 2 1 2 Ethernet Interface COMpact 4000...
Page 91: ...COMpact 4000 V05 10 2018 91 Ethernet 1 2 230 V LED Status LED Power LED LED Power...
Page 95: ...COMpact 4000 V05 10 2018 95 3 10 m J Y St Y 2 x 2 x 0 6 ISDN...