Commissioning
36
COMpact 4000 - Instructions V05 10/2018
outside of the power supply unit (for instance ringer voltages). Work on active, contact-
hazardous parts is only permitted after creating a voltage-free state. Working close to
active parts is only permitted if these parts are voltage-free or are protected against direct
contact.
• Disconnect the power plug of the PBX and the accessories before instructing a qualified
electrician to open the casing. Also disconnect the device from additional power sources
(e. g. UPS, if installed).
• Wait at least 3 minutes for the discharge of any capacitor in the device after
disconnecting it from the main power supply.
• Only operate the device when the casing is closed.
• Only operate the device mounted on the wall.
Warning:
Power surges, which may occur during electrical storms, can cause life-
threatening electric shocks, or damage or destroy the PBX.
• Do not touch the PBX or any devices connected to it during an electrical storm.
1. Unlatch both locks simultaneously by
compressing each with thumb and
index finger.
2. Lift the cover and remove it
completely from the casing.
Wall-Mounting the PBX
Warning:
Touching voltage-carrying conductors or telephone connections can
cause life-threatening electric shocks.
• Mount the PBX close of an earth wire (potential compensation bar of the house
installation or protective earth conductor). Connect the PBX's earth connection to the
earth wire with a connecting cable whose conductor diameter is at least 2.5 mm
²
.
Warning:
Liquid entering the casing can cause life-threatening electric shocks or
damage or destroy the PBX.
• Only operate the PBX in closed, dry rooms.
Caution:
Overheating can damage or destroy the system.
•Note the ambient temperature values indicated in the technical data.
• Make sure that heat produced by the device can be adequately vented into the
environment. Do not install the system in a cabinet without adequate air circulation.
• Never cover the air vents of the casing.
Important:
Mechanical loads and electro-magnetic fields can impair PBX operation.
• Avoid mechanical loads (e. g. vibrations).
• Avoid the proximity of devices that generate electro-magnetic fields (e. g., radio sets,
professional radio equipment, amateur radio equipment, mobile phones, DECT systems,
WLAN routers, etc.).
Summary of Contents for COMpact 4000
Page 77: ...COMpact 4000 V05 10 2018 77 2 5 mm...
Page 78: ...78 COMpact 4000 V05 10 2018 14 6 EMVG DECT...
Page 79: ...COMpact 4000 V05 10 2018 79 PIN IP wireshark NAT www bsi bund de TK Anlagen COMpact 4000...
Page 80: ...80 COMpact 4000 V05 10 2018 230 VAC 10 50 Hz 0 5 A I 6 W 48 W 0 40 20 70 10 90...
Page 87: ...COMpact 4000 V05 10 2018 87 3 1 2 2 5 mm...
Page 89: ...COMpact 4000 V05 10 2018 89 3 2 5 mm2 1 2 3...
Page 90: ...90 COMpact 4000 V05 10 2018 COMpact 2BRI 1 2 1 2 1 2 Ethernet Interface COMpact 4000...
Page 91: ...COMpact 4000 V05 10 2018 91 Ethernet 1 2 230 V LED Status LED Power LED LED Power...
Page 95: ...COMpact 4000 V05 10 2018 95 3 10 m J Y St Y 2 x 2 x 0 6 ISDN...