Connecting ISDN End Devices
50
2.
Attach the wires to the two middle terminal clamps in
the internal U
P0
port. See
.
3.
With an ISDN wall socket: Connect the IAE or UAE8
socket to the terminal clamps on the internal U
P0
port.
,
and
Only U
P0
/S
0
adapters: Connect both screw terminals
at the back of the U
P0
/S
0
adapter to the terminal
clamps on the internal U
P0
port. See
.
4.
With an ISDN wall socket: If necessary, connect the
U
P0
/S
0
adapter.
Further Steps
쑱
Connect the end devices to the wall socket or to the
connection sockets on the U
P0
/S
0
adapter.
쑱
To finish commissioning, you need to set up an
internal phone number for each end device in the
COMset configuration manager.
Fig. 48: COMfortel 1100/1500/2500/2500 AB via
an ISDN wall socket
Internal U
P0
port
on the PBX
max. 1000 m with 0.6 mm
얒
Fig. 49: Connection over a fixed U
P0
/S
0
adapter
Internal U
P0
port
on the PBX
max. 1000 m with 0.6 mm
얒
Fig. 50: Connection via a U
P0
/S
0
adapter and an
ISDN wall socket
Internal U
P0
port
on the PBX
max. 1000 m with 0.6 mm
얒