Preparation (Casing Variants for Wall Mounting)
30
2.
Drill the mounting holes (
쏗
6 mm) and insert dowels
into the holes.
3.
Fasten the mounting frame on the wall using the
screws.
Reinstalling the Mounting Rack
Requirements
– Mounting frame fastened on the wall
Steps to Take
Note: To prevent the cable in the USB casing socket
from becoming pinched, roll up the cable and place it
near the socket in the cable space.
1.
Hold the mounting rack diagonally with the upper
edge towards the wall and install it at the top in the
mounting frame. See
2.
In addition, press the lower part of the mounting rack
onto the mounting frame until the lock snaps in.
Connecting the Earthing
Requirements
– Hand tools and material:
Screw driver
Connecting cable with at least 2.5 mm² conductor
cross-section
– Earth wire in the immediate vicinity of the mounting
location
Warning. Umproper handling of the device can result
in life-threatening electrical shock.
씮
Only a skilled electrician may open the casing and
perform installation work within an open casing.
씮
Mount the PBX in the immediate vicinity of an
earth wire (potential compensation bar of the
house installation or protective earth conductor).
씮
Only a fixed installation is allowed for the connec-
tion of the earthing terminal of the PBX to the
potential compensation bar of the house installa-
tion or the protective earth conductor. Plug con-
nections are not allowed.
Warning. Touching voltage-carrying conductors or
telephone connections may cause a life-threatening
electric shock.
씮
The PBX contains hazardous voltages, even out-
side of the power supply unit (for instance ringer
voltages). Work on active, contact-hazardous
parts is only permitted after creating a voltage-
free state.
Working close to active parts is only permitted if
these parts are voltage-free or are protected
against direct contact.
씮
Pull out the power plug of the PBX before com-
missioning a skilled electrician to open the casing
to perform switching or connecting services.
씮
If available, also disconnect the devices from
auxiliary power sources (for example, UPS).
Steps to Take
•
Connect the earthing terminal on the main cirnuit
board of the PBX via the connecting cable to the po-
tential compensation bar of the house installation or
the protective earth conductor. See
2.
Fig. 20: Reinstall the mounting rack
1.