Commissioning
59
You will then hear the confirmation tone
(pulsating tone).
3.
Hang up the receiver.
The telephone rings.
The setting is shown on the display.
4.
Pick up the receiver and then hang it back up again in
order to end the call and display.
Connecting the PC to the Ethernet Port
Warning: Touching voltage-carrying conductors or
telephone connections may cause a life-threatening
electric shock.
씮
The PBX contains hazardous voltages, even out-
side of the power supply unit (for instance ringer
voltages). Work on active, contact-hazardous
parts is only permitted after creating a voltage-
free state.
Working close to active parts is only permitted if
these parts are voltage-free or are protected
against direct contact.
씮
Casing variants for wall mounting: Pull out the
power plug of the PBX before commissioning a
skilled electrician to open the casing to install the
expansion module or perform switching or con-
necting services.
씮
19“ casing variants: The Power button switches
the voltage at the module expansion slots and on
the main circuit board off. If the system is switched
off, a skilled electrician can be commissioned to
install expansion modules or to perform switching
or connecting services.
씮
If available, also disconnect the devices from
auxiliary power sources (for example, UPS).
Requirements
– Minimal distance between the devices
– The crossover cable contained in the package.
Steps to Take
1.
Insert one end of the crossover cable into the network
socket on the computer.
2.
Insert the other end of the crossover cable into the
Ethernet socket on the PBX.
Note: If the Ethernet port is required for the Internet
connection, you need to connect the PC to the router.
For more information, contact your system
administrator. See
Note: In order to connect the PC to the router, you
need a patch cable (not included in the delivery).
Connecting the PC to the USB Port
Warning: Touching voltage-carrying conductors or
telephone connections may cause a life-threatening
electric shock.
씮
The PBX contains hazardous voltages, even out-
side of the power supply unit (for instance ringer
voltages). Work on active, contact-hazardous
parts is only permitted after creating a voltage-
free state.
Working close to active parts is only permitted if
these parts are voltage-free or are protected
against direct contact.
씮
Casing variants for wall mounting: Pull out the
power plug of the PBX before commissioning a
skilled electrician to open the casing to install the
expansion module or perform switching or con-
necting services.
씮
19“ casing variants: The Power button switches
the voltage at the module expansion slots and on
the main circuit board off. If the system is switched
off, a skilled electrician can be commissioned to
install expansion modules or to perform switching
or connecting services.
씮
If available, also disconnect the devices from
auxiliary power sources (for example, UPS).
Important: When using the operating systems
Windows 7 and Windows Vista: First of all (before
connecting the device to the PC) start the driver
installation from the Auerswald Mega Disk (as of
version 5.95).
Requirements
– Minimal distance between the devices
Important: The length of the USB cable may be a
maximum of 3 m total.
## 8
*
94 0 #
Query the DHCP client status.
## 8
*
94 1 #
Query the IP address.
## 8
*
94 2 #
Query the subnet mask.
## 8
*
94 3 #
Query the gateway address.