Version 5.8
57
June 2009
Installation Manual
4. Monitoring the Device
4 Monitoring
the
Device
The operating status of the device can be monitored in the following ways:
Monitoring the device's hardware front-panel LEDs (refer to 'Front-Panel LEDs' on
page
57
).
Monitoring the device using the Web interface (refer to 'Web Interface' on page
58
).
4.1
Front-Panel LEDs
The location of the device's front panel LEDs are shown in the figure below and described
in the subsequent table.
Figure
4-1: Location of Front-Panel LEDs
Table
4-1: Analog I/O (FXS / FXO) Modules LEDs Description
I/O Port LED
Color
State
Description
RJ-11
Green On
FXS: phone is off-hooked.
FXO: off-hooks the line toward the PBX.
Blinking
FXS: rings the extension line.
FXO: detects a ring signal from the PBX.
Red
On
Error (malfunction in line).
Table
4-2: E1/T1 PRI I/O TRUNKS Modules LED Description
LED
Color
State
Description
RJ-48c
Green
On
Trunk is synchronized (normal operation).
Red
On
Loss due to any of the following signals:
LOS - Loss of Signal
LOF - Loss of Frame
AIS - Alarm Indication Signal (the Blue Alarm)
RAI - Remote Alarm Indication (the Yellow Alarm)
-
Off
Failure / disruption in the AC power supply or the power is
currently not being supplied to the device through the AC
power supply entry.
Summary of Contents for Mediant 1000
Page 1: ...Document LTRT 83505 June 2009 Installation Manual Version 5 8 ...
Page 2: ......
Page 10: ...Installation Manual 10 Document LTRT 83505 Mediant 1000 Reader s Notes ...
Page 56: ...Installation Manual 56 Document LTRT 83505 Mediant 1000 Reader s Notes ...
Page 61: ...Version 5 8 61 June 2009 Installation Manual 4 Monitoring the Device Reader s Notes ...
Page 62: ...Installation Manual Version 5 8 www audiocodes com ...