Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not
permitted unless authorised by AUDI AG. AUDI AG does not guarantee or accept any liability
with respect to the correctness of information in this document. Copyright by AUDI AG.
– Remove bolts -E-.
– Remove bolt -B- and remove bracket -C- downward.
– Pull fluid reservoir -D- upward out of condenser -A- -arrow-
Note
Seal open connections on reservoir and condenser with suitable
caps (to prevent dirt and moisture from entering).
Installing
Note
There are different versions of the condenser and bracket -C- de‐
pending on the production time period. As a running change in
MY 2007, the mounting was changed from a metal bracket at‐
tached by screws to a plastic bracket held in place by a clip.
• Tightening specification: Bolts for securing fluid reservoir on
condenser - 10 Nm.
Installation is done is reverse order, observe the following:
Note
♦
Coat the O-ring seals lightly with refrigerant oil prior to instal‐
⇒ “1.21 Refrigerant Circuit O-rings“, page 41
.
♦
Check O-ring seals for proper seating in grooves -arrows- on
respective mount.
♦
Keep fluid reservoir closed as long as possible; do not remove
caps until just before installing. Fluid reservoir contains a dryer
cartridge which will become saturated with moisture in a short
time if accumulator is left open. This makes the accumulator
unusable.
Audi TT 2007 ➤
Heating, Ventilation and Air Conditioning - Edition 01.2011
5. Removal and Installation
177