Au Group Electronics
Au SAE J1939 Simulator (Gen II) 2.00A User Manual Rev. D
13
Figure 3-7 Power, Range, 20%, 40%, 60%, 80% are constant on, “
▲
100%” LED blinks, indicating data reaches 100%
•
▼
0%
LED will be triggered on or off when pressing
Down
button, accompany with the decreasing brightness of
Range LED. A press on the
Down
button will also decrease the control step value and all simulated data. When
the control step value equals to 0%,
▼
0% LED blinks.
The control step value vs. LED indicator status is summarized in Table 3-2.
Table 3-2
Control step value vs. LED indicator status (in Static Mode)
Step
Operation
LED Status
1 Connect
+12~+24 V DC
power supply
Power, Range
LED on, the rest LED will recall
the last saved status at Static mode
2
Press
Down
button
▼
0%
LED on/off
3 Continue
press
Down
button until control step value = 0%
▼
0%
LED blink
4
Press
Up
button
▲
100%
LED on/off
5 Continue
press
Up
button for control step value 1 to 19%
Power, Range
LED constant on
6
Continue press
Up
button for control step value 20%
Power, Range
LED on,
20%
LED Blink
7 Continue
press
Up
button for control step value 21 to 39%
Power, Range
LED on,
20%
LED on
8
Continue press
Up
button for control step value 40%
Power, Range, 20%
LED ON,
40%
LED Blink
9 Continue
press
Up
button for control step value 41 to 59%
Power, Range, 20%, 40%
LED on
10 Continue press
Up
button for control step value 60%
Power, Range, 20%, 40%
LED on,
60%
LED
blink
11 Continue
press
Up
button for control step value 61 to 79%
Power, Range, 20%, 40%, 60%
LED on
12 Continue press
Up
button for control step value 80%
Power, Range, 20%,40%, 60%
LED on,
80%
LED blink
13 Continue
press
Up
button for control step value 81 to 99%
Power, Range, 20%, 40%, 60%, 80%
LED on
14 Continue press
Up
button for control step value 100%
Power, Range, 20%, 40%, 60%, 80%
LED on,
▲
100%
blink