5
Specified min.temperature of returnable water in operation is 65°C.
Specified temperature of water during operation in the boiler is 80-90°C.
Technical parameters:
ATTACK, s.r.o. producer reserves the right to change technical parameters and dimensions of boilers without previous warning.
DP25 DP35 DP45 DP75 DP95
25 35 45 75 95
10-25 14-35 18-45 30-75 43-95
1,52 1,74 1,95 3,60 5,60
96 112 128 305 440
235x445 235x445 235x445 292x542 292x542
23 23 23 23 25
250 250 250 250 250
370 405 430 650 800
150 150 150 219 219
1235 1235 1235 1320 1535
690 690 690 750 766
1090 1190 1295 1600 1750
590 690 790 1100 1100
21 21 21 21 21
50 50 60 60 90
85 85 86 86 81
3
230 225 220 262 287
0,019 0,021 0,027 0,045 0,059
65 65 65 65 65
7,75 9,75 11,75 18,7 29,2
550 650 750 1000 1000
3 3 3 3 3
68 78 87 164 250
600 900 1200 1800 2375
230/50
3
1kW = 1m
65-90
10-27
230 / 2
kW
kW
2
m
3
dm
mm
Pa
kPa
kg
mm
mm
mm
mm
IP
W
%
°C
kg/s
dB
-1
kgh
mm
hod.
l
l
V/Hz
°C
°C
V/A
mm
Type of boiler
Boiler output
STANDARDversion )
Output range (
PROFIversion)
Heating surface
Feed hopper capacity
Dimensions of feeding opening
Prescribed chimney drought
Max.operating pressure of water
Weight of boiler
Diameter of the flue connection
Boiler height - "A"
Boiler width - "B"
Boiler depth - "C"
The depth of the chamber - "D"
Shield of the electric parts
Electrical input
Boiler efficiency
CO emission class
Flue gas temperature in nominal output
Flow of flue gas in nominal output
Maximum noise level
Prescribed fuel
Average fuel consumption
Max. length of wood logs
Burning time in min. output
Volume of water in the boiler
Range of temperature of heating water
Min.volume of equalisation basin
Connection voltage
Consumption per season
Range of room tempereature
( PROFIversion)
Current carrying capacity
of boiler regulator contacts (PROFI version)
Dry wood of 15-17 Mj/kg-1 calorific value,water content
min. 12% - max. 20% diameter 80-150mm
Summary of Contents for DP PROFI
Page 1: ...W W W A T T A C K S K WOOD GASIFYING BOILER ATTACK DP STANDARD PROFI INSTRUCTIONS FOR USE ...
Page 2: ......
Page 32: ...31 ...
Page 35: ...34 ATTACK DP STANDARD 95 ...
Page 37: ...36 ATTACK DP PROFI 95 ...
Page 39: ......