4. TS2 Virtual Cabinet Emulator
Minimum Flash Programming
Since there is no definite instance when the virtual cabinet is powered up, the
Minimum Flash Time is not implemented in the virtual MMU
. However,
the minimum flash programming will be properly reflected in the Type 129
MMU Inputs/Status response frame.
Voltage Monitoring Latch Programming
Since TVC-3800 is connected to the Controller Unit through an SDLC bus,
the Virtual MMU cannot monitor the CVM on the CU. It also does not have a
24V power supply. Thus, +24V Latch and CVM/Fault Monitor Latch are
only reflected in the Type 129 MMU Inputs/Status response frame.
To open advanced settings click
button. This will expand the
window and add the following section:
The following options are available under the advanced category:
Disable Yellow Monitoring
Selecting this option disables monitoring of yellow signals on user selected
channels by the internal virtual MMU. This option can be used with
controller configurations where the Yellow from a pedestrian channel is used
for alternate functions.
To apply changes and close the
MMU Setup
dialog window, click
OK
button.
To discard any changes and close the
MMU Setup
dialog window, click
Cancel
button.
MMU Programming Card configuration can be saved to be quickly loaded in the
future. To save a predefined configuration type the name of the configuration in
the
Predefined Configuration
box and click
Save
button. Click
OK
to confirm
the operation in the opened message box.
Note: Only alpha-numeric (a-z, A-Z,0-9), _ (underscore), - (minus), and
space characters are allowed in the configuration names. Any other typed
character will be replaced with an underscore ( _ ).
To load a predefined configuration, click on of the
Predefined Configurations
drop down box and select the name of the configuration to be loaded. Click
OK
button in the opened message box to confirm the operation.
TVC-3800 User's Manual, Rev. 1.0
13