![Atop SW5501 User Manual Download Page 43](http://html1.mh-extra.com/html/atop/sw5501/sw5501_user-manual_3004804043.webp)
SW5501 – SW5502
Wireless Serial Server
User Manual
Configuration and
setup
Regulatory Domain
–
This
can be selected from 4 options in the drop
-
down list box
:
CN
(
APL1_WORLD
)
,
EU
(
ETSI2_WORLD
)
, TW
(
APL3_FCCA
)
, US
(
FCC5_FCCA
)
, and VN
(
ETSI3_WORLD
).
Note that different
Regulatory Domains will result in different radio channels
/
frequencies being allowed SW550X to operate
(
see
Channel
setting in previous subsection
).
Disconnected Detection
–
When this option is checked, SW550X will use
the Ping command to check whether
the wireless connection between SW550X and a
target device is still active
.
When the Disconnected Detection
is already enabled and the mentioned connection is disconnected, SW550X will re
-
initiate wireless connection
again after a certain period of time
which can be set in the Time option
(
next line
).
The reconnection time can
be set between 30 and 300 seconds
.
The target device can be specified by entering its IP address in the
Target IP option
.
Note that the user should ensure that SW550X can establish the connection with its target
device first
.
STP
–
The Spanning Tree Protocol is only available in the AP Client mode
.
Enable this option if STP is enabled
in the user
’
s network to prevent network loops by setting up the Forward Delay time
.
When disabled, SW550X
will not forward STP Bridge Protocol Data Units
(
BPDUs
).
Note that
if Wireless Profile
(Paragraph 4.4.1
) f
eature is enabled, Fast Handoff, Fast Roaming and
Roaming Threshold, and STP
options will not be presented and supported, as shown below
.
Figure 4.32
Wireless Advanced Settings Page when Wireless Profile is Enabled
After finish configuring the Advanced Settings, please click on
“
Save & Apply
”
button to keep the change that you
have made
.
A pop
-
up window with a message
“
Please wait for a while
…”
will appear briefly
.
Then, another pop
-
up
window with message
“
The settings have been completed
”
will be displayed
.
When the saving and applying
are
finished, the pop
-
up window will disappear and the web browser will be redirected to the Operation Mode page
.
If
you want to cancel the change and reset all changes back to their original values, just click the Cancel button
.