EN
www.atmos.cz
50-EN
Operation and Maintenance Manual - EN
• Fan speed -
displays the
current speed of the fan
• Fan speed 2 –
displays the
current speed of fan 2 (not used)
• Conveyor -
displays the
current status of the conveyor
• Conveyor faults -
displays
information for the service engineer
• Spirals -
displays
the current status of the ignition spirals
• Spiral faults -
displays
information for the service engineer
• Reserve R -
displays the
current status of the reserve output R (parameter S6)
• Reserve R2 -
displays the
current status of the reserve output R2 (parameter S14)
• Reserve R5 -
displays the
current status of the reserve output R5 (parameter S67)
• Reserve R6 -
displays the
current status of the reserve output R6 (parameter S68)
TESTING menu
• Autotest
– This function is used for automatic testing of all the basic elements of the burner as the
fan, conveyor, ignition spirals, etc. The testing is carried out consecutively in 20-second intervals
so that the engineer can monitor the operation of individual devices.
If this test is not sufficient, individual devices can be run separately, namely with the use of the
following functions.
CAUTION
– During testing the burner is put out of operation, therefore before the start of
testing always let the burner properly burn out
with the use the STOP command.
• Fan
- this function is used to test the operation of the fan
• Conveyor
- this function is used to test the operation of the conveyor
• Spiral 1
- this function is used to test the operation of the ignition spiral 1
• Spiral 2
- this function is used to test the operation of the ignition spiral 2
• Reserve R
– this function is used to test the switching device (relay) of the reserve output R
• Reserve R2
– this function is used to test the switching device (relay) of the reserve output R2
• Reserve R5
– this function is used to test the switching device (relay) of the reserve output R5
• Reserve R6
– this function is used to test the switching device (relay) of the reserve output R6
• Photocell
- used to test the photocell. Conduct the test by observing its sensitivity when it is
inserted in the burner or outside the burner in the natural light (never on the sun – will cause an alarm).
Summary of Contents for A85
Page 1: ...Operation and Maintenance Manual EN www atmos cz Operation and Maintenance Manual ...
Page 2: ...www atmos cz Operation and Maintenance Manual EN ...
Page 61: ...Operation and Maintenance Manual EN EN www atmos cz EN 61 20 Expanded view of the burner ...
Page 66: ...EN www atmos cz 66 EN Operation and Maintenance Manual EN Notes ...