EN
www.atmos.cz
48-EN
Operation and Maintenance Manual - EN
• Offset TV
– This function is used to compensate the offset of the TV temperature sensor
(input) in the range of ± 9.9 °C.
• Offset TS
– This function is used to compensate the offset of the TS temperature sensor
(input) in the range of ± 9.9 °C.
• Offset TK – This function is used to compensate the offset of the TK temperature sensor (in-
put) in the range of ± 9.9 °C
• Offset TSV – This function is used to compensate the offset of the TSV temperature sensor
(input) in the range of ± 9.9 °C
• Reset
– By means of this function you can use one command to reprogram the electronic unit
of the burner to the default settings.
• Restart – By means of this function you can use one command to reprogram the electronic unit
of the burner to the settings last set by the installer (under the installer code).
This allows the resetting of the control unit without changing the system settings in case of any
problems.
• Calibr.
– This function makes it possible to calibrate inputs for temperature sensors with the use of
special calibration aids –
function for the manufacturer only.
• Language
– This is the selection function of the language in which the burner communicates with
the user.
The basic version of the program contains these language versions:
CZ - Czech
DE - German
EN - English
FR - French
IT - Italian
SP - Spanish
SE - Swedish
PO - Portuguese
RO - Romanian
PL - Polish
HU - Hungarian
Summary of Contents for A85
Page 1: ...Operation and Maintenance Manual EN www atmos cz Operation and Maintenance Manual ...
Page 2: ...www atmos cz Operation and Maintenance Manual EN ...
Page 61: ...Operation and Maintenance Manual EN EN www atmos cz EN 61 20 Expanded view of the burner ...
Page 66: ...EN www atmos cz 66 EN Operation and Maintenance Manual EN Notes ...